Rev 0, Jun/2000 15610M00.RCD Page 5-33
TEST DATA SHEET
C. VOR deflection (internal CDI)
Set the generator to the 0° from radial. Note a centered VOR deflection.
Change the units OBS setting to that indicated below and confirm the deviation
indicated.
OBS 350° _________________ Deviation output within 1 increment of full
scale right.
OBS 10° _________________ Deviation output within 1 increment of full
scale left.
D. Digital VOR Bearing
Observe the bearing radial in the VOR Bearing mode (Ref. fig. 3-5; TO indica-
tion) and in the VOR Radial mode (Ref. fig. 3-7; FROM indication).
ERROR LESS THAN 2°
BEARING RADIAL
DISPLAY DISPLAY
RADIAL (TO) (FROM)
0° _________ _________
30° _________ _________
60° _________ _________
90° _________ _________
180° _________ _________
270° _________ _________