EasyManua.ls Logo

Honeywell BENDIX/KING KY 96A - Page 24

Honeywell BENDIX/KING KY 96A
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
B KY 96A, KY 97A
Rev 4, Apr 2003 IM 006-00674-0004.dwd Page 2-10
FIGURE 2-4 Molex Terminal and Tools (Sheet 3 of 3)
Once
the
terminal
is
in
the
correct
position,
close
the jaws
gently
until
the
terminal
is
held
loosely
in
place.
Push
wire stop
down
so
that
it
rests
snugly behind the
contact
portion
of
the
terminal.
Strip
the wire
insulation
back
1/8
inch
and
insert
the wire through the
insulation
tabs
into
the
conductor tabs
until
the
insulation
hits
the conductor jaw face
or
until
the conductor touches the
wire
stop.
WIRE
STOP
ION
Squeeze
the
handles
until
the crimp jaws
close
and
the
ratchet
releases.
Straighten
the terminal
if
necessary,
then
release
the
plier
grips
and
remove
the crimped
terminal.
CRIMPING
PRESSURE
ADJUSTMENT
If
too
much
or
too
little
pressure
is
needed to
release
the
crimper's
ratchet
pawl
at
the
end
of
the crimp
stroke,
the
ratchet
can
be
easily
adjusted.
A spanner wrench provided with the
tool
can
be
used to loosen the lock
nut,
and
rotate
the
keyed
stud
clockwise
for
increased
pressure
and
counter-clockwise
for
decreased
pressure.
Once
the
desired
pressure
has
been
set,
the
lock nut
must
be
tightened
again.
Newer
models
may
have a
screwdriver
ad.iustment.
KEYED
STUD
SPANNER
WRENCH
NUT
(OPPOSITE SIDE)

Related product manuals