BWRigRat I.S. Barrier
Installation Guide
Rev. A
P/N: W03-4017-000
Step 1
Remove the four screws holding the cover
in place, and then lift off the cover.
Step 2
Pull out the input and output connectors.
Step 3
Pass wires through the glands on the exterior of the
case and then connect the wires to their terminals on
each connector,
Step 4
Plug connectors back into the barrier. Then
secure the wires. And tighten the glands.
Glands
Step 5.1
Mounting on concrete or brick wall
before or after wiring.
Step 5.2
Mounting on wooden wall before or
after wiring.
Step 5.3
Mounting on sheet or plate metal
(<30mm thick).
Step 6
Secure the back cover by tightening the four
screws.
The BW RigRat User’s Guide should be
read and understood before installing
or using the BW RigRat I.S. Barrier. It is
available at: safety.honeywell.com
The following instructions cover installation and wiring the BW RigRat I.S. Barrier. This equipment should
only be connected in accordance with applicable regulations by qualified personnel.
DC OUT
AC IN

Other manuals for Honeywell BW RigRat

Questions and Answers:

Honeywell BW RigRat Specifications

General IconGeneral
DisplayLCD
Warranty2 years
Target GasesH2S, CO, O2, LEL
Detection PrincipleElectrochemical (O2, CO, H2S), Catalytic (LEL)
RangeH2S: 0-100 ppm, CO: 0-500 ppm, O2: 0-30% vol, LEL: 0-100% LEL
SensorsH2S, CO, O2, LEL
Ingress ProtectionIP66
AlarmsVisual, audible, and vibration alarms

Related product manuals