Mark V and Mark VII EGPWS Pilot’s Guide
060-4241-000 Smart Runway
®
Rev H, August 2011 69
RAAS Quick
Reference
Continued
34L 16R
34R
16L
11
29
“On Runway Three-Four Left,
Six-Hundred Remaining”
“Caution Short Runway, Short Runway”
Insufficient Runway / Caution
Runway Entry
Conditions for caution:
· All conditions for a non-routine
Insufficient Runway advisory are
satisfied; and
· Runway length available is less
than nominal take-off runway length
· Aircraft groundspeed > 40 knots
34L 16R
34R
16L
11
29
“On Runway Three-Four Left,
On Runway Three-Four Left”
Extended Holding On Runway
Runway Occupancy
Conditions for advisory:
· Aircraft on runway
· Within 20 deg. Of runway heading
· Waiting in position for extended
period that is operator defined
e.g. 90 seconds