Communications [56] Galaxy Flex Installer Manual
154
Audio [56.6]
Use this option to setup Audio Transmission to allow audio verification of an alarm. Each
system zone can be assigned one audio channel, each with a maximum of three
microphones. Following an alarm transmission over PSTN, you can program the panel to
route recorded audio from the time of the alarm activation, and live audio, direct to the
Alarm Receiving Centre. The following options are available:
 1 = Listen In ((0 = Disabled, 1 = Enabled)
 2 = Audio Channels
 Select Audio Channel ((0 = Disabled, 1 = Enabled)
 3 = Pre-Alarm – Pre Listen Time 00 (0 to 10 sec, the default is 5)
Listen In [56.6.1]
Use this option to allow onsite audio verification by an operator, after the panel sends an
alarm signal to the ARC (0=Disabled, 1=Enabled).
Audio Module [56.6.2]
Use this option to control the audio channels’ status. Select an audio channel to enable or
disable.
The channel is in a four-digit format. For example: Channel 9024.
9=Line number (fixed)
0=Audio Interface number (fixed)
2=Mux Module number
4=Audio channel
Press ent to display the status of the current audio channel, f
or example:
Press ent again to disable the audio channel.
Pre-Alarm [56.6.3]
Use this option to set the alarm delay recording time. The audio channel continuously
records a rolling 10 seconds of audio. When an alarm activation occurs, the system stops
recording and stores 10 seconds of audio. Use the pre-listen time parameter to set the
amount of alarm delay in the recorded audio.
Pre-Listen Time
The alarm delay listen time can be set from 0 to 10 seconds. Setting the time to 5 seconds
(d
efault) means that 5 seconds of pre-alarm and 5 seconds of post alarm audio is saved.
CHANNEL 9024
[ent] to select
ENABLED 9024 E
0=DISABLED
E = enabled, D = disabled

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Flex 100 V3 and is the answer not in the manual?

Honeywell Galaxy Flex 100 V3 Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy Flex 100 V3
CategorySecurity System
LanguageEnglish

Related product manuals