Galaxy Flex Installer Manual Appendix D: Specifications
211
Appendix D: Specifications
Mechanical
Panel enclosure
width: 337 mm
height: 333 mm
depth: 93 mm
weight as supplied:
M version
337 mm
333 mm
93 mm
1.8 kg
L version
367 mm
393 mm
98 mm
2 kg
Operating temperature 10°C to + 55°C
Maximum battery size 151 x 65 x 115 mm 180 x 75 x 170 mm
Humidity 0 to 85%
Battery capacities 4 Ah Yuasa
7 Ah Yuasa
9 Ah Yuasa Yucel
10 Ah Yuasa
17 Ah Yuasa (L variant only)
Electrical
Mains input 230 V (+10%, −15%) @ 50Hz
Control panel current consumption 140 mA maximum
Power supply Type A
Battery type Sealed lead-acid, plastic enclosure
Max ripple voltage 150 mV pk-pk
M version L version
Maximum auxiliary current rating 0.9 A 1.8 A
EN grade 2 maximum auxiliary current rating 0.7 A 1.3 A
Minimum standby battery capacity required for
maximum load (EN50131/PD6662 @ 12 h)
8.4 Ah 17 Ah
Maximum Battery Size 10 Ah 17 Ah
Time to recharge Battery to 80% 67 h
Total PSU output 1 A 2 A
Aux voltage output 13.8 V nominal (10 V to 14.5 V)
APS fault 10.7 V nominal
Switched outputs:
Output 1 400 mA maximum sink current
Output 2 400 mA maximum sink current
Output 3 (speaker) 8 to 32 ohms
PTC ratings:
AUX1 1.1 A
BATT 3 A
Data retention 10 years @ 150°C

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Flex 100 V3 and is the answer not in the manual?

Honeywell Galaxy Flex 100 V3 Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy Flex 100 V3
CategorySecurity System
LanguageEnglish

Related product manuals