Galaxy Flex Installer Manual Appendix G: Peripherals
239
Configuration
Note: MAX
4
readers can only be configured into the system from engineer mode.
1. Access engineer mode.
2. Check that Access Mode [69.1] is enabled.
3. Configure the reader as On-Line or Standalone using MAX Address [69.2.1]: 0=On-
Line, 1=Standalone (default).
4. Press ent. The panel may prompt for the AB line (1 – 4) that is to be searched; select
the line and press ent. The panel searches for the MAX
4
with the highest address. New
MAX
4
readers are addressed as 8 (standalone) by default.
5. Only if adding a new MAX
4
reader: On locating the MAX
4
address, the keypad
prompts for the OPERATING MODE of MAX
4
to be assigned: select 0=On-Line or
1=Standalone as required and press ent. When 0=On-Line mode is selected, the keypad
displays the current address of the MAX
4
and the range of valid addresses. Enter the
n
ew MAX
4
address and press ent. The keypad indicates the old and new MAX
4
addresses and the status of the reprogramming.
Note: We recommend addressing new readers with the lowest available number on
the line.
When reprogramming is complete the MAX
4
bleeps, the LEDs on the MAX
4
switch off
and the keypad display returns to 1=MAX Address.
6. Enter your engineer code, and then press esc to exit from engineer mode. The message
1 MOD. ADDED - esc=CONTINUE is displayed on the keypad and LED 2 on the
MAX
4
reader switches on. Press esc and the keypad returns to the unset banner.
If this message is not displayed, the MAX
4
reader is not communicating with the
control panel and has not been configured into the system (LED 2 does not switch on).
The online MAX
4
reader is now configured into the system.
Operating instructions
Opening the door without presenting a valid card activates a door forced alarm at the panel;
the buzzer sounds and LED 2 flashes until the door is closed.
Activating the egress switch allows the door to be opened without activating an alarm when
no card has been presented to the MAX
4
.
1. Ensure that LED 3 is on and all other LEDs are off.
2. Swipe the reader with a standard user or nightlock access user card. LED 3 switches off
and LED 2 switches on for the programmed Open Timeout.
3. Open the door while the LED 2 is on and access the area.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Flex 100 V3 and is the answer not in the manual?

Honeywell Galaxy Flex 100 V3 Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy Flex 100 V3
CategorySecurity System
LanguageEnglish

Related product manuals