Group Omit [46] Galaxy Flex Installer Manual
74
When you select the option the groups assigned to the user code and keypad are displayed as
well as the omit status of each group (Y below the group indicates that it is omitted, N
indicates that it is not omitted).
To omit a group, press the required key. The letter beneath the group number changes from
N to Y. To reinstate the group press the key to toggle from Y to N.
Notes:
1. The type 6 user must have group choice to enter Group Omit.
2. The zones in the selected groups are omitted from the system as soon as the group is
selected and ZONES OMITTED is displayed.
Omitted zones remain omitted for one set period only or until they are manually reinstated
to the system.
Outputs programmed as Zone Omit (mode programmed as reflex) are activated as soon as
the zone is omitted and remains active until the zone is reinstated. If the output mode is
programmed as latch, then the Zone Omit outputs activate when the system is set and remain
active until the system is unset, reinstating the omitted zones.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Flex 100 V3 and is the answer not in the manual?

Honeywell Galaxy Flex 100 V3 Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy Flex 100 V3
CategorySecurity System
LanguageEnglish

Related product manuals