Galaxy Flex Installer Manual Parameters [51]
97
0=Disable Exits Exit type zones will only cause unconfirmed intruder alarms. They will
not contribute to the two activations required for a confirmed alarm.
1=Enable Exits After the expiry of the entry delay, activation of an exit type zone will
be identical to an intruder zone.
Confirm Reduce Reset [51.55.3]
Use this option to allow user reset following an unconfirmed alarm.
0=Off Full system reset is required for any intruder alarm.
1=On Unconfirmed The system can be reset by a user if the alarm is unconfirmed.
If the alarm is classed as confirmed, a full system reset is required.
Timeout Confirm [51.55.4]
Use this option to define if an Entry Time-out alarm will contribute to a confirmed alarm
0=Disabled Time-out will not contribute (PD6662: 2004)
1=Enabled Time-out will contribute (PD6662: 2010)
HU Confirm [51.55.5]
Use this option to define if a confirmed Hold-up alarm condition should be generated from
two separate Panic or hold-up zone types.
0=Disabled Confirmed Hold-up condition will not be generated
1=Enabled Confirmed Hold-up condition will be generated
HU Time [51.55.6]
Use this option to define the maximum time window between two separate panic zone
activations to generate a confirmed hold-up event. (1-20 hours)
Output type 20 response [51.55.7]
Use this option to define what events the Standard Confirm output type (type 20) will
respond to.
0=Confirmed Intruder events only
1=Confirmed Intruser and Confirmed Hold-up and even ts
A separate output type is also available for confirmed hold-up events only (type 84)
Force Restore [51.56]
Use this option to select when intruder restore signals are transmitted.
1=Unset/Unconfirm On unset or at the end of the confirmed time if the alarm is not
confirmed.
2=System Reset Sent when the system is fully reset.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Flex 100 V3 and is the answer not in the manual?

Honeywell Galaxy Flex 100 V3 Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy Flex 100 V3
CategorySecurity System
LanguageEnglish

Related product manuals