Appendix A 
 
 
241 
14  Appendix A 
Connecting Alarm Input/Outputs 
This appendix contains the following sections: 
•  Before Connecting Alarm Inputs and Outputs, on page 241 
•  Alarm Input and Output Rear Panel Connections, on page 241 
•  Guidelines for Connecting Local Alarm Input Ports, on page 242 
•  Guidelines for Connecting Alarm Output Ports, on  page 242 
Before Connecting Alarm Inputs and Outputs 
•  Ensure that the alarm input mode is set to ground. 
•  Ensure that the signal is grounded. 
•  Know that the alarm inputs require low-level voltage signals. 
•  Ensure that the alarm input mode is set to either NC (normally closed) or NO (normally 
open). 
•  Use a relay if you are connecting two NVRs, or a NVR plus another device, to separate 
them. 
•  Do NOT directly connect the alarm output port to a high-power load. The load should be 
less than 1 A to avoid damage. 
•  Use the contactor to make the connection between the alarm output port and the load. 
Alarm Input and Output Rear Panel Connections 
The connections for the alarm input and output channels are described below: 
Table 14-1 Alarm Input and Output Rear Panel Connections 
Input/Output  Description 
1 to 4 
Alarms inputs 1 to 4. The inputs becomes active with 
low voltage. 
NO1 C1, NO2 
C2 
Normally open activation outputs (on/off) 
Ground