Page #8 background imageLoading...
Page #8 background image
Installation Guide
69-2198—01 6
HEAT PUMP
Fig. 13. Zone panel wiring—heat pump, 2-heat/1-cool with electric auxiliary heat.
Use the following diagram for wiring a 2-heat/1-cool heat pump with electric auxiliary heat.
NOTE: You can use a conventional thermostat for a heat pump system; however, em heat can only be controlled by
heat pump thermostats. The diagram below shows a heat pump thermostat used with a heat pump system.
1
2
1
2
1
2
3
3
1
2
1
2
Rc
R
C
E
AUX
Y
G
O/B
L
Rc
R
C
E
AUX
Y
G
O/B
L
Rc
R
C
E
AUX
Y
G
O/B
L
Rc
R
C
E
AUX
Y
G
O/B
L
ALTERNATIVELY LABELED W2 ON SOME THERMOSTATS.
FOR THERMOSTATS WITH SEPARATE O AND B TERMINALS, ATTACH O FOR
COOL CHANGEOVER VALVES, AND ATTACH B FOR HEAT CHANGEOVER VALVES.
IF EQUIPMENT DOES NOT HAVE SEPARATE E AND W2 TERMINALS, JUMPER
E TO W2 ON PANEL AND WIRE TO E.
HZ432
HEAT 1
HEAT 2
HEAT 3
COOL 1
COOL 2
PURGE
FAN
EM HEAT
ZONE 1
ZONE 2
ZONE 3
ZONE 4
EMERGENCY
HEAT
M1
M4
M6
R
C
W1/E
W2
W3
Y1
Y2
G
O/B
L
M1
M4
M6
R
C
W1/E
W2
W3
Y1
Y2
G
O/B
L
M1
M4
M6
R
C
W1/E
W2
W3
Y1
Y2
G
O/B
L
RH
RC
W1/E
W2
W3
Y1
Y2
G
O
B
DS/BK
HOME
CONFIG
CHECK OUT
ADJUST SETTING
M4 OPEN
M6 CLOSED
M1 COMMON
M24794
ARD OR ZD DAMPER
SPRING-OPEN
POWER-CLOSED
DEDICATED
TRANSFORMER
R
C
L1
(HOT)
L2
AIR
HANDLER
FAN RELAY
EM. HEAT
AUX. HEAT
HEAT PUMP
G
Y
24 VOLT TRANS.
C
R
Y
E
C
R
W2
ARD OR ZD DAMPER
SPRING-OPEN
POWER-CLOSED
ARD OR ZD DAMPER
SPRING-OPEN
POWER-CLOSED
M1
M4
M6
R
C
W1/E
W2
W3
Y1
Y2
G
O/B
L
DATS
DATS
OT
OT
AZ1
AZ2
ZONE 4
DAMPER
THERMOSTATEQUIPMENT
POWERSENSORS
A
B
C
D
ACCESSORIES
ZONE 2
DAMPER
THERMOSTATZONE 1
DAMPER
THERMOSTAT ZONE 3
DAMPER
THERMOSTAT
R
C
C7089U1006
OUTDOOR
TEMPERATURE
SENSOR
C7735A1000
DATS
WIRELESS
ADAPTER
RRD OR MARD DAMPER
POWER-OPEN
POWER-CLOSED
REVERSING
VALVE
WIRELESS
CONNECT
POWER
THM4000R
CONNECTED
WIRELESS SETUP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell HZ432 TrueZONE and is the answer not in the manual?

Honeywell HZ432 TrueZONE Specifications

General IconGeneral
Zones4
Power Supply24 VAC
LED IndicatorsYes
Auxiliary Heat Stages2
Conventional Stages2
Transformer40 VA
Maximum Current1A per zone
Wire Gauge18-22 AWG
ExpandableYes
Wiring18-22 AWG
Humidity Range5% to 90% RH, non-condensing
Thermostat CompatibilityStandard 24 VAC thermostats