LYNX Touch Installation and Setup Guide
- 73 -
SIA Quick Reference Guide
Programming Section Feature Range Shipping Default SIA Requirement
Installation and Setup Guide or Programming Guide
Reporter/
Report Selection
Exit Error Enabled or Disabled Enabled Enabled
Recent Closing Enabled or Disabled Enabled Enabled
Alarm Cancel Enabled or Disabled Enabled Enabled
Reporter/Options
Call Wait Cancel Enabled or Disabled
Field is blank (a PBX prefix
is entered to enable)
Enabled if User has call
waiting
Number of Reports 1 to 6 Reports 2 Reports 2 Reports
Alarm Report Delay 15, 30 and 45 seconds 30 Seconds 30 Seconds*
System Settings
Entry Delay # 1
30, 45, 60 and 90 seconds
and 2, 3 or 4 minutes
30 Seconds 30 Seconds minimum
Entry Delay # 2
30, 45, 60 and 90 seconds
and 2, 3 or 4 minutes
30 Seconds 30 Seconds minimum
Exit Delay
45, 60, 90 seconds and 2
minutes
60 Seconds 45 seconds minimum
Restart Exit Time Enabled or Disabled Yes (Enabled) Enabled
Exit Warning Not selectable Always enabled Enabled
Auto Stay Arming Enabled or Disabled Yes (Enabled) Enabled
Cross Zone Delay
30 seconds and 2 minutes
(in 30 second increments),
3 minutes and 4 minutes
None (Disabled)
Enabled and two zones
programmed
Zones
Fire Alarms
Zone Type “Fire with
Verification” must be
selected for Fire Zone 95
Disabled Disabled
User Guide
User Functions/
User Access
Duress
Duress Code is
Programmed by Master
User as User 16
Disabled Disabled
System Functions/
Testing the System**
System Test
System tests provided as a
User Function
n/a n/a
Communications
While the system is in Test
mode, no alarm reports are
sent to the central station
Disabled Disabled
* Combined Entry Delay and Abort Window should not exceed 1 minute.
** Refer to the User Guide for procedures on Testing the System.
Note: Using the Call Waiting Cancel feature on a non-Call Waiting line will prevent successful communication to the central station.

Table of Contents

Other manuals for Honeywell LYNX Touch Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell LYNX Touch Series and is the answer not in the manual?

Honeywell LYNX Touch Series Specifications

General IconGeneral
ZonesUp to 64 wireless zones
Integrated CameraNo
Voice PromptsYes
EncryptionYes
CommunicationWi-Fi, Cellular
Backup BatteryYes
Alarm NotificationsYes
SirenBuilt-in siren
Remote AccessYes
DisplayColor touchscreen

Related product manuals