18
Data Field Descriptions
35
Entry Delay 01
 HQWU\ GHOD\ WLPH LQ VHFRQGV
The system will wait the time entered before sounding alarm upon entering
if system is not disarmed. UL installations: must be set for a maximum of
45 seconds
36
Entry Delay 02
 HQWU\ GHOD\ WLPH LQ VHFRQGV
The system will wait the time entered before sounding alarm upon
entering. UL installations: must be set for a maximum of 45 seconds
37
Audible Exit Warning/Quick Exit
([LW :DUQLQJ 4XLFN ([LW
QR H[LW ZDUQLQJ
VRXQG
QR TXLFN
H[LW
SURYLGH H[LW
ZDUQLQJ VRXQG
ZKHQ DUPHG $:$<
DOORZ TXLFN
H[LW
Exit Warning: Sound consists of slow continuous beeps until last 5 seconds,
when it changes to fast beeps. The warning sound will end at the
termination of exit delay.
Quick Exit: If enabled, user can restart the exit delay time after arming in
STAY mode by entering the user code and pressing the
STAY
key, or by
pressing the
STAY
key if Quick Arm is enabled. This avoids having the
user disarm then re-arm the system after allowing someone to enter or exit
38
Confirmation of Arming Ding
QR GLQJ
FRQILUPDWLRQ GLQJ DIWHU DUPLQJ V\VWHP
FRQILUPDWLRQ GLQJ DIWHU DUPLQJ IURP 5) EXWWRQ RU
5) NH\SDG RQO\
Confirmation of arming is provided by a 1/2 second external sounder ding
that sounds when closing report is sent, or at the end of exit delay.
If Option 2 is selected the external sounder ding occurs immediately after
the system receives the RF transmission.
39
Power Up In Previous State
DOZD\V SRZHU XS LQ D GLVDUPHG VWDWH
DVVXPH WKH V\VWHP VWDWXV SULRU WR SRZHUGRZQ
When the system powers up armed, an alarm will occur 1 minute after
arming if a zone is faulted, and any bypassed zones will be unbypassed.
Note: If the previous state was armed
AWAY
or
STAY
, the system will not
respond to sensor changes for 1 minute, which allows time for sensors such
as PIRs to stabilize. UL installations: must be 1 (power up in previous
state)
DIALER PROGRAMMING (
40
50)
Fields
40,
41,
42:
Enter up to the number of digits shown. Enter 09, # + 11 for
*
;
# + 12 for #; # + 13 for a pause
(2 seconds)
NOTE:
Whenever AAV is used, primary (field
41) and secondary (field
42) phone numbers should be preceded with the call waiting
disable command. Otherwise, there is the possibility of connection of the third party to LYNX during AAV mode.
40
PABX Access Code
(QWHU XS WR GLJLWV LI 3$%; LV QHHGHG WR DFFHVV DQ
RXWVLGH OLQH
If fewer than 6 digits need to be entered, exit by pressing []. To clear
entries from field, press 40.
41
Primary Phone No.
(QWHU XS WR  GLJLWV
If fewer than 20 digits entered, exit by pressing []. To clear entries from
field, press 41.
Note:
Backup reporting (8 attempts are made to the secondary phone
number if no kissoff is received after 8 attempts to the primary
number) is automatic only if there is a secondary phone number
(field 42).
42
Secondary Phone No.
(QWHU XS WR  GLJLWV
If fewer than 24 digits entered, exit by pressing []. To clear entries from
field, press 42. See backup reporting note for field 41. If using the
paging feature, enter the pager phone number here.
$OO IRXU GLJLWV RI
WKH 6XEVFULEHU $FFRXQW QXPEHU PXVW EH HQWHUHG LQ )LHOGV
 DQG
 ,I WHQ GLJLW IRUPDW LV
VHOHFWHG LQ
 RSWLRQ DOO WHQ GLJLWV RI WKH 6XEVFULEHU $FFRXQW QXPEHU PXVW EH HQWHUHG
Fields
43 and
44:
Enter [
]
as the fourth digit if a 3-digit account number (for 3+1 dialer reporting format) is used. Enter 0 as the first
digit of a 4-digit account number for Nos. 00000999. Enter [
] as the fifth digit if a 4-digit account number (for 3+1,
CID®) is used. Exit field by pressing [
] if only 3 digits are used. To clear entries from field, press
43
or
44
. See
blank Programming Form for examples of account number entries. If using the paging feature, do not enter a leading 0
in the subscriber account number, and do not use digits A-F anywhere in the number. Some paging systems provide
voice mail capability, which is activated by a leading 0 in the message. Enter digits 09; # +11=B; # +12=C; # +13=D; #
+14=E; or # +15=F.
43
Primary Subs Account No.
(QWHU D IRXU RU WHQ GLJLW DFFRXQW QXPEHU
Enter the primary subscriber account number.
To clear entries from field, press 43.
44
Secondary Subs Account No.
(QWHU D IRXU RU WHQ GLJLW DFFRXQW QXPEHU
Enter the secondary subscriber account number.
To clear entries from field, press 44.

Other manuals for Honeywell LYNXR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell LYNXR and is the answer not in the manual?

Honeywell LYNXR Specifications

General IconGeneral
BrandHoneywell
ModelLYNXR
CategorySecurity System
LanguageEnglish

Related product manuals