Lyric Controller Installation and Reference Guide
- 30 -
Programming Default
Programming Default Programming Default
Programming Default Values
ValuesValues
Values
Program Function
Program FunctionProgram Function
Program Function
Default Value
Default ValueDefault Value
Default Value
Program Function
Program FunctionProgram Function
Program Function
Default Value
Default ValueDefault Value
Default Value
Installer Code
4112 Test Enabled
System Type
Test Restore Enabled
RF Jam RF Jam Log
Bypass Enabled
RF House Code 0 Bypass Restore Enabled
Events - Log All Press to Log All
AC Loss Enabled
Events - Log Alarm Enabled AC Loss Restore Enabled
Events - Log Bypass Enabled Low Battery Enabled
Events - Log Open/Close Enabled Low Battery Restore Enabled
Events - Log Trouble Enabled RF Low Battery Enabled
Non Security Enabled RF Low Battery Restore Enabled
Remote Access Serial Disabled Options
Multi Mode Serial Disabled Number of Reports 2 Reports
Date Time
Alarm Report Delay 30 Sec.
Calendar January 1, 2013 First Report Offset 6 Hrs
Enter Time 12:00 PM
Report Frequency Never
Time Zone Eastern (EST)
Sounder
Day Light Savings time Yes Burglary Alarm Sound Yes
Start Month March Burglary Bell Timeout 4 Minutes
Start Week Second Fire Bell Timeout 4 Minutes
End Month November Arm Confirm RF Key fob
End Week First
System Settings
Communicator
Entry Delay 1 30 Seconds
Communications Path WiFi Entry Delay 2
30 Seconds
APL Enabled
Exit Delay 60 Seconds
City ID Blank Backlight Timeout
No
CS ID
Blank
Quick Arm Yes
Sub ID
Blank
Quick Exit Yes
Supervision 30 Days
Restart Exit Time Yes
Old Alarm Time 10 Minutes
Force Bypass No
Remote Acc. Comm. Disabled Exit Warning Yes
Multi Mode Comm. Disabled Auto Stay Arming Yes
WiFi Fault Time (min) 00 Lack Of Usage Notify Disabled
Use DHCP Yes Power-Up In Previous Yes
NIC IP Address 255.255.255.255 Display Alarm Cancel Yes
Subnet Mask 255.255.255.255 Display Exit Time Yes
Gateway IP Address 255.255.255.255 (A) Cross Zone Delay None
DNS Server IP Address 255.255.255.255 (A) Cross Zone 1 Disabled
GSM Fault Time 60 (A) Cross Zone 2 Disabled
GSM Rollover No (B) Cross Zone Delay None
GSM 24 Hour Test No (B) Cross Zone 1 Disabled
Zones (See Zone Programming Default Configuration)
(B) Cross Zone 2 Disabled
Keys (See Zone Programming Default Configuration)
(C) Cross Zone Delay None
Reporter
(C) Cross Zone 1 Disabled
Report Selection (C) Cross Zone 2 Disabled
Arm Away Enabled (D) Cross Zone Delay None
Arm Stay Enabled (D) Cross Zone 1 Disabled
Disarm Enabled (D) Cross Zone 2 Disabled
Exit Error Enabled
Z-Wave
Recent Closing Enabled Z-Wave Enabled
Event Log Full Enabled Temperature Fahrenheit
Trouble Enabled
Language
Trouble Restore Enabled Installer Language English
Alarm Restore Enabled User Language English
Alarm Cancel Enabled
RF Keypad (See Zone Programming Default Configuration)