33
69-1012
Heating will not come on.
(Continued)
Jumper wires R and W. If heat does not come on, contact
your heating dealer.
If display is blank or shows
bAt Lo
, install fresh batteries.
If temperature setting is higher than current temperature,
and the display shows HEAT, contact Honeywell
Customer Assistance at 1-800-468-1502.
Cooling will not come on. Check that the switch on the thermostat is set to COOL.
Check the system fuse or circuit breaker and replace or
reset if necessary.
Check for correct wiring and good connections.
Jumper wires Rc and Y. If cooling does not come on,
contact your cooling dealer.
If display is blank or shows
bAt Lo
, install fresh batteries.
The thermostat has a built-in time delay on cooling. Allow
five to ten minutes after changing the setting before the
air conditioner starts.
Make sure the outdoor disconnect is energized (on).

Questions and Answers: