TABLE 3: ANSI Z359.14 and CSA Z259.2.2: Inspection Requirements
Type of Use
Application
Examples
Conditions of Use
Worker
Inspection
Frequency
Competent
Person
Inspection
Frequency
APPLIES TO CSA
ONLY Product
Revalidation
Frequency
Infrequent
to Light
Rescue & con-
fined space,
Factory
maintenance
Good storage conditions,
indoor or infrequent outdoor
use, room temperature,
clean environments
Before each
use
Annually At least every
5 years but not
more than inter-
vals required by
the manufacturer
Moderate to
Heavy
Transportation,
Residential
construc-
tion, Utilities,
Warehouse
Fair storage conditions, in-
door and extended outdoor
use, all temperatures, clean
or dusty environments
Before each
use
Semi-annually
to annually
At least every
2 years but not
more than inter-
vals required by
the manufacturer
Severe to
Continuous
Commercial
construction,
Oil & Gas,
Mining
Harsh storage conditions,
prolonged or continuous
outdoor use, all tempera-
tures, dirty environment
Before each
use
Quarterly to
semi-annually
At least annually
but not more than
intervals required
by the manufac-
turer
1) Failure of a worker to perform “before each use” inspection or failure of an inspection by a worker shall initiate the requirement for inspection by a
competent person.
2) Failure of a competent person to perform inspections as specified in this Table, or failure of an inspection by the competent person shall initiate product
revalidation or disposal.
3) Determination of the type of use category shall be determined by a competent person.
4) A SRL that is considered non-repairable, or not designed for disassembly such that internal inspection is not possible without rendering it unserviceable, is
not subject to revalidation inspection. These SRLs shall have service life and other inspection requirements as provided by the manufacturer’s instructions.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell MILLER TURBOLITE+ Series and is the answer not in the manual?

Honeywell MILLER TURBOLITE+ Series Specifications

General IconGeneral
BrandHoneywell
ModelMILLER TURBOLITE+ Series
CategorySafety Equipment
LanguageEnglish

Related product manuals