WATER CONDENSATION DRAINAGE
When there is excess water condensation inside the unit, the air conditioner stops running and shows a
warning light (the Power Control button flashes with a red light). This warning light indicates that the
water condensation needs to be drained using the following procedures:
Manual Draining for AC & Dehumidifier Mode
Water may need to be drained in high humidity areas.
Continuous Draining for Dehumidifier Mode
While using the unit in dehumidifier mode, continuous
drainage is recommended.
WATER CONDENSATION DRAINAGE
1.
2.
3.
4.
5.
6.
Unplug the unit from power source.
Place a shallow pan under the lower drain plug.
See diagram.
Remove both the plastic cap and lower drain plug.
Water will drain out and collect in the shallow pan.
After the water is drained, replace the lower drain plug
firmly.
You can now turn on the unit.
1.
2.
3.
4.
5.
6.
Unplug the unit from the power source.
Remove the upper drain plug.
Some residual water may spill so please have a pan to
collect the water.
Connect the drain connector to a ¾” hose or standard
garden hose (not included).
See diagram.
The water can be continuously drained through the
drain tube into a floor drain or bucket.
Replace the drain plug.
You can now turn on the unit.
Plastic Cap
& Lower
Drain Plug
Shallow Pan
(Not included)
Drain Tube
Upper
Drain Plug
EN 9