Fig. 15. Hookup diagram in oil heating/electric cooling system (oil primary has its own transformer).
S1
S
T1
T
OUT
OUT
LED
G
Y2
Y1
W1
W2
1
2
3
4
GND
C
R
RH
RC
HUM
HUM
VNT
VNT
W8900A,C
L1
(HOT)
L2
1
2
L1
(HOT)
L2
1
6
3
1
2
3
4
5
4
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
DURING INSTALLER SETUP, CONFIGURE PC8900 FOR HUMIDITY CONTROL IN HEATING MODE
(HUMIDIFIER) OR COOLING MODE (DEHUMIDIFIER).
W8900 ALLOWS CONNECTION OF A CO MONITOR WITH UNCOMMITTED CONTACTS.
SEE VENTILATION INSTRUCTIONS FOR WIRING.
GROUNDING THE GND TERMINAL IS NOT RECOMMENDED.
CONNECTION FOR CM8900A REMOTE COMMUNICATIONS MODULE.
FAN RELAY
PC8900
1
2
3
4
CO
2
MONITOR
M4490D
STAGE 1
COOL RELAY
T
T
OIL PRIMARY
HUMIDIFIER OR
DEHUMIDIFIER
EQUIPMENT
VENTILATION
EQUIPMENT
CO
2
SYSTEM
TRANSFORMER
C7189A REMOTE AIR
TEMPERATURE SENSOR
C7100 DISCHARGE AIR
TEMPERATURE SENSOR
C7089A OUTDOOR AIR
TEMPERATURE SENSOR
2
6
5