EasyManuals Logo

Honeywell RTH5100B Quick Installation Guide

Honeywell RTH5100B
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
TROUBLESHOOTINGASSISTANCESETUP WIRING
17 69-2329EF—03
RTH5100B
Next
12
0
Done
MCR29544
Function 12: Manual/Auto Changeover
Press the s or t button to select Manual or Auto Changeover:
NOTE: System maintains a minimum 3ºF
difference between heat and cool settings.
CAUTION: To avoid possible compressor
damage, set to option 0 if the outside
temperature drops below 50ºF (10ºC).
0 Manual Changeover: (Heat/Off/Cool)
1 Automatic Changeover: (Heat/Off/Cool/Auto) Automatically turns on
heat or cool based on room temperatures.
Press to change setting.
When correct setting is
selected, press NEXT to
display next function.
MCR29540