EasyManua.ls Logo

Honeywell RTH6500WF - Wiring Your Thermostat; Conventional System Wiring

Honeywell RTH6500WF
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
69-2718ES—01 14
Installing your thermostat
Wiring (conventional system)
7A Wire the Wi-Fi thermostat to your conventional system.
a Starting with the C Wire, match the sticky tag on the
wire to the terminal labels.
You must have a C wire. See page 13.
b Loosen screw, insert wire on inside edge
of terminal, then tighten screw.
c Verify wire is firmly secured by gently
pulling on wire.
d Repeat steps a–c for all other wires.
e Push any excess wire back into the wall
opening after all wires are installed.
f Continue to page 20.
Labels don’t match? See alternate
wiring key on pages 16–17.
W2
G W
YR RCK
Y2
C
MCR33878
Y
HEAT PUMP
CONVENTIONAL
AUX/E
G O/B
YRRCK
L
C
C
G
W
R
Remove metal jumper
only if you have both
R and RC wires
Note: The wiring for your
application might be different
from the wiring shown above.