S8600B,C,H,M; S8610B,C,H,M; S8670D,E,J,K INTERMITTENT PILOT GAS IGNITION CONTROL
บริษัท เอดีดี เฟอร์เนส จํากัด
ADD FURNACE CO.,LTD.
44 ซอยบรมราชชนนี 70 ถนนบรมราชชนนี แขวงศาลาธรรมสพน์ เขตทวีวัฒนา กรุงเทพฯ 10170
โทร: 02-888-3472 โทร: ออกแบบ:08-08-170-170 แฟกซ์: 02-888-3258
https://www.add-furnace.com E-mail: sales@add-furnace.com
GND 24V
MV MV/PV PV
(BRN) GND
24V
DUAL VALVE COMBINATION
GAS CONTROL
COMBUSTION
AIR BLOWER
RELAY
LIMIT
CONTROLLER
AIR BLOWER
BURNER
MOTOR
GROUND
PILOT GAS
SUPPLY
PILOT BURNER/
IGNITER-SENSOR
GND 24V
MV MV/PV PV
(BRN) GND
24V
MAIN VALVE
MAIN
STAGE 2
VALVE
PILOT COM GROUND
STAGE 1
1ST 2ND
OPERATOR OPERATOR
TWO STAGE DUAL VALVE
COMBINATION GAS CONTROL
COMBUSTION
AIR BLOWER
RELAY
PILOT
BURNER/
IGNITER-
SENSOR
PILOT
BURNER
GROUND
PILOT GAS
SUPPLY
GND 24V
MV MV/PV PV
(BRN) GND
24V
DUAL VALVE COMBINATION
GAS CONTROL
COMBUSTION
AIR BLOWER
RELAY
LIMIT
CONTROLLER
PILOT BURNER/
IGNITER
AIR BLOWER
MOTOR
L2 L1 (HOT)
S8600 B,C; S8610 B,C
S8600 H,M; S8610 H,M; S8670 D,E
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
ALTERNATE LIMIT CONTROLLER LOCATION.
MAXIMUM CABLE LENGTH 3 FT. [0.9 M].
(HOT)
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
ALTERNATE LIMIT CONTROLLER LOCATION.
MAXIMUM CABLE LENGTH 3 FT. [0.9 M].
CONTROLS IN 24V CIRCUIT MUST NOT BE IN GROUND LEG TO TRANSFORMER.
M29902
CONTROLS IN 24V CIRCUIT MUST NOT BE IN GROUND LEG TO TRANSFORMER.
M29900
Fig. 6. S8600 H,M; S8610 H,M; S8670 D,E connections
in a heating system with a two-stage gas control and
Fig. 4. S8600 B,C; S8610 B,C connections with remote
flame sensing in a heating system with an
atmospheric burner.
power-assisted combustion.
S8600 B,C; S8610 B,C; S8670 J,K
S8600 H,M; S8610 H,M; S8670 D,E
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
ALTERNATE LIMIT CONTROLLER LOCATION.
MAXIMUM CABLE LENGTH 3 FT. [0.9 M].
ALTERNATE LIMIT CONTROLLER LOCATION.
MAXIMUM CABLE LENGTH 3 FT. [0.9 M].
CONTROLS IN 24V CIRCUIT MUST NOT BE IN GROUND LEG TO TRANSFORMER.
M29903
CONTROLS IN 24V CIRCUIT MUST NOT BE IN GROUND LEG TO TRANSFORMER.
M29901
Fig. 7. S8600 B,C; S8610 B,C; S8670 J,K connections
with remote flame sensing in a heating system with
power-assisted combustion.
Fig. 5. S8600 H,M; S8610 H,M; S8670 D,E connections
in a heating system with power-assisted combustion.
GND 24V
MV MV/PV PV
(BRN) GND
24V
DUAL VALVE COMBINATION
GAS CONTROL