EasyManua.ls Logo

Honeywell TH8320R1003 - Set up Dehumidification Away Mode

Honeywell TH8320R1003
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VISIONPRO
®
8000 WITH REDLINK™
68-0312—03 86
Fig. 202.
Set up Dehumidification Away Mode
1. Select Allowed at ISU 918. See Fig. 203.
Fig. 203.
2. Set Fan Control settings. See Fig. 204.
On: Fan is always on.
Automatic: Fan runs only when cooling system is on.
Circulate: Fan runs randomly, about 35% of the time.
Fig. 204.
3. Set temperature and dehumidification settings. See Fig.
205.
Low Limit Temperature Setting
If the cooling system is used to control humidity while
Dehumidification Away Mode is active, the thermostat
allows the cooling system to lower the indoor air to the
Low Limit Temperature Setting to reach the
Dehumidification Setting at ISU 920.
Temperature Setting
The temperature maintained while Dehumidification
Away Mode is active and the desired humidity level is
satisfied.
Dehumidification Setting
The desired humidity level while Dehumidification
Away Mode is active.
Fig. 205.

Table of Contents

Related product manuals