Installation Guide
8
69-2486—07
Setup functions Settings & Options (factory default in bold)
0250 2nd stage heat
cycle rate (CPH)
9 Electric furnaces
1 Steam or gravity systems
3 Hot water systems & furnaces of 90%+ efficiency
5 Gasoroilfurnacesoflessthan90%efficiency
[Other options: 2, 4, 6, 7, 8, 10, 11, 12 CPH]
0260 3rd stage heat cycle
rate (CPH)
9 Electric furnaces
1 Steam or gravity systems
3 Hot water systems & furnaces of 90%+ efficiency
5 Gasoroilfurnacesoflessthan90%efficiency
[Other options: 2, 4, 6, 7, 8, 10, 11, 12 CPH]
0270 Emergency heat
cycle rate (CPH)
9 Electric emergency heat
1 Steam or gravity systems
3 Hot water systems & furnaces of 90%+ efficiency
5 Gasoroilfurnacesoflessthan90%efficiency
[Other options: 2, 4, 6, 7, 8, 10, 11, 12 CPH]
0280 Continuous
Backlight
0 Backlight on for approx. 45 seconds after keypress
1 Backlight always on low intensity, full bright after keypress
(requires24VACconnection)
0300 Manual/Auto
changeover
0 Manual changeover (Heat/Cool/Off)
1 Automatic changeover (Heat/Cool/Auto/Off)
0310 Auto changeover
deadband
3 Heat/cool temperature 3°F apart (1.5°C)
[Other options: 2-9 (2°F to 9°F/1°C to 5°C)])
0320 Temperature
display
0 Fahrenheit
1 Celsius
0330 Daylight savings 1 Auto-change to daylight savings time (through 2007, and for
areas that do not use the new 2008 DST calendar)
0 Daylight savings time is turned off
0500 Furnace lter
change reminder
0 Off
1 10-day run time (about 1 month)
2 30-day run time (about 3 months)
3 60-day run time (about 6 months)
4 90-day run time (about 9 months)
5 120-day run time (about 1 year)
6 180-day run time (about 1.5 years)
7 270-day run time (about 2 years)
8 365-day run time (about 3 years)
9 30 calendar days
10 60 calendar days
11 90 calendar days
12 120 calendar days
13 180 calendar days
14 365 calendar days
0502 Furnace lter
for Run time
0 Counts both heat and cool
1 Counts cool only
0520 UV Lamp
Replacement
Reminder
0 Disabled
1 365 days
2 730 days
0530 Adaptive Intelligent
Recovery™
1 On
0 Off
Installer setup
Continued on next page