EasyManua.ls Logo

Honeywell TH8320ZW1000 - Core Operational Settings; Setting the Clock and Time

Honeywell TH8320ZW1000
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation Guide
8
69-2486—03
Setup functions Settings & Options (factory default in bold)
0250 2nd stage heat
cycle rate (CPH)
5 Gas or oil furnaces of less than 90% efficiency
1 Steam or gravity systems
3 Hot water systems & furnaces of 90%+ efficiency
9 Electric furnaces
[Other options: 2, 4, 6, 7, 8, 10, 11, 12 CPH]
0260 3rd stage heat
cycle rate (CPH)
5 Gas or oil furnaces of less than 90% efficiency
1 Steam or gravity systems
3 Hot water systems & furnaces of 90%+ efficiency
9 Electric furnaces
[Other options: 2, 4, 6, 7, 8, 10, 11, 12 CPH]
0270 Emergency heat
cycle rate (CPH)
9 Electric emergency heat
1 Steam or gravity systems
3 Hot water systems & furnaces of 90%+ efficiency
5 Gasoroilfurnacesoflessthan90%efficiency
[Other options: 2, 4, 6, 7, 8, 10, 11, 12 CPH]
0280 Continuous
Backlight
0 Backlight on for approx. 45 seconds after keypress
1 Backlight always on low intensity, full bright after keypress
(requires24VACconnection)
0300 Manual/Auto
changeover
0 Manual changeover (Heat/Cool/Off)
1 Automatic changeover (Heat/Cool/Auto/Off)
0310 Auto changeover
deadband
3 Heat/cool temperature 3°F apart (1.5°C)
[Other options: 2-9 (2°F to 9°F/1°C to 5°C)])
0320 Temperature
display
0 Fahrenheit
1 Celsius
0330 Daylight savings
1 Auto-change to daylight savings time (through 2007, and for
areas that do not use the new 2008 DST calendar)
0 Daylight savings time is turned off
0500 Furnace lter
change reminder
0 Off
1 10-day run time (about 1 month)
2 30-day run time (about 3 months)
3 60-day run time (about 6 months)
4 90-day run time (about 9 months)
5 120-day run time (about 1 year)
6 180-day run time (about 1.5 years)
7 270-day run time (about 2 years)
8 365-day run time (about 3 years)
9 30 calendar days
10 60 calendar days
11 90 calendar days
12 120 calendar days
13 180 calendar days
14 365 calendar days
0502 Furnace lter
for Run time
0 Counts both heat and cool
1 Counts cool only
0520 UV Lamp
Replacement
Reminder
0 Disabled
1 365 days
2 730 days
Installer setup
Continued on next page

Other manuals for Honeywell TH8320ZW1000

Related product manuals