The following table shows the values the Vibrex unit has
assigned to the text labels in the Prop Balance Quality screen:
Label
IPS Reading
Best
Less than 0.05
Very good
0.05 to 0.09
Good
0.10 to 0.14
Acceptable
0.15 to 0.19
Unacceptable
0.20 to 1.19
Warning
Greater than 1.20
There are two additional context keys for use during the balance
operation, as follows:
DONE Press when the balance level is
at the desired point and there is
no need to make any more
changes.
INSTALL PERMANENTLY Press if the user needs to move
the weight inside the spinner.
Pressing this key accesses the
Split Weights and Radius
Change menus.