VisionPRO
®
IAQ
7
0502
0510
0520
0530
0540
0570
0580
0600
0610
0620
0630
0640
0650
0660
0670
0680
0690
Furnace filter
alert options
Humidifier pad
change alert
UV lamp change
alert
Adaptive Intelligent
Recovery
™
Program periods
Non-compressor
off time (min.)
Compressor off
time (min.)
Heat temperature
range stop
Cool temperature
range stop
Non-compressor
on time (min.)
Compressor on
time (min.)
Clock format
Extended fan
timer (heat)
Extended fan
timer (cool)
Keypad lock
Heat temperature
control
Cool temperature
control
0 Timer counts Heat & Cool run time
1 Timer counts Cool run time only
E Auto Discover **
0Off
1 90 calendar days (about 30 days run time)
2 180 calendar days (about 60 days run time)
3 365 calendar days (about 90 days run time)
E Auto Discover **
0Off
1 365 calendar days (1 year)
2 730 calendar days (2 years)
1 On **
0Off
4 4 program periods (Wake, Leave, Return, Sleep)
2 2 program periods (Wake, Sleep)
0Off
[Other options: 1 to 5 minutes]
5 5 minute compressor off time **
[Other options: 0 to 4 minutes]
90 Max. heat temperature setting is 90°F (32°C)
[Other options: 40 to 90°F (4°C to 32°C)]
60 Min. cool temperature setting is 60°F (15°C)
[Other options: 60-99°F (15°C to 37°C)]
0Off
[Other options: 1 to 15 minutes]
0Off
[Other options: 1 to 15 minutes]
12 12-hour time (i.e., “3:30 pm”)
24 24-hour time (i.e., “15:30”)
0Off
[Other options: Fan runs for 30, 60, 90 or 120 seconds after
call for heating ends]
0Off
[Other options: Fan runs for 30, 60, 90 or 120 seconds after
call for cooling ends]
0 Keypad unlocked (fully functional)
1 Partially locked (access to temperature settings only)
2 Fully locked
2 Standard temperature control (recommended)
1 Choose if room is warmer than set temperature
3 Choose if room does not reach set temperature
2 Standard temperature control (recommended)
1 Choose if room is cooler than set temperature
3 Choose if room does not reach set temperature
** See page 8
Installer setup (English: Page 4 • Français: Page 10 • Español: Página 16)
Setup functions Settings & Options (factory default in bold)