Over-cooling limit
Dehumidification
fan action
Away mode
Away mode
fan setting
Away mode low
limit temp.
Away mode temp.
setting
Away dehumidifi-
cation setting
Ventilation control
Number of
bedrooms
Size of house
Ventilation level
Max. ventilation
% limit
Ventilation fan
action
Ventilation in high
humidity
Furnace filter
change alert
3 3°F (1.5°C)
[Other options: 1, 2 (1°F or 2°F/0.5°C to 1.5°C)]
0 System fan turns on with dehumidifier
1 Dehumidifier operates independent of fan
0No
1Yes
0 Fan auto
1 Fan always on
2 Fan circulate
76 Low limit temperature 76°F (24°C)
[Other options: 70°F to 80°F (21°C to 27°C)]
85 Away temperature 85°F (29°C)
[Other options: 70°F to 99°F (21°C to 37°C)]
65 Away humidity level 65%
[Other options: 55% to 70%]
0 No ventilation
1 Ventilation always allowed
2 Ventilation not allowed during sleep period
2 Two bedrooms
[Other options: 1 to 6]
10 1,000 square feet
[Other options: 11 to 50 (1,100 to 5,000 square feet]
160 CFM (cubic feet per minute)
[Other options: (30 to 195 CFM)]
50 50% ventilation limit
[Other options: 30% to 60%]
P Meets ASHRAE 62.2 standard
F Does not meet ASHRAE 62.2 standard
1 Ventilation on forces fan on
2 Ventilation does not force fan on
1 On (heat mode only)
0Off
Installer setup (English: Page 4 • Français: Page 10 • Español: Página 16)
Setup functions Settings & Options (factory default in bold)
SOUTHERN DEHUMIDIFICATION AWAY SETTINGS
E Auto Discover **
0Off
1 10-day run time
2 30-day run time
3 60-day run time
4 90-day run time
5 120-day run time
6 180-day run time
7 270-day run time
8 365-day run time
9 30 calendar days
10 60 calendar days
11 90 calendar days
12 120 calendar days
13 180 calendar days
14 365 calendar days