23 69-2761EFS—03
Adjusting dehumidification settings: commercial use
This feature can control a dehumidifier or
use your air conditioner to reduce humidity.
1 Touch MENU and select Dehumidification.
2 Select Auto.
3 Touch s or t to select humidity level.
4 Touch Done to save your settings. Touch
Cancel to ignore changes.
If your air conditioner is used to control
humidity, the thermostat may use the
following methods to maintain humidity:
Cool from 1° to 5° F lower than your
temperature setting.
Run cooling for the minimum “on” time to
reduce humidity.
Run cooling and heating at the same
time to reduce humidity without lowering
the temperature.
MCR34130
Dehumidification
Equipment Status
MCR34131
Dehumidification
Off Auto