∗49 Split/Dual Reporting [0]
0 = Standard/backup reporting only (all to primary)
Primary Phone No. 2nd Phone No.
1 = Alarms, Restore, Cancel Others
2 = All except Open/Close, Test Open/Close, Test
3 = Alarms, Restore, Cancel All
4 = All except Open/Close, Test All
5 = All All
∗
∗∗
∗50 Burglary Dialer Delay [2,0]
Delay Time: Delay Time V21iPSIA
0 = no delay UL: must be “0” Delay Disable
1 = 15 seconds; 2 = 30 seconds; 3 = 45 seconds
SIA Guidelines: delay must be minimum of 15 seconds
V21iPSIA:
Delay Time: 1 = 15 seconds; 2 = 30 seconds; 3 = 45 seconds
Delay Disable:
0 = use delay set in entry 1
1 = dial delay disabled for zones listed in zone list 6 (use zone list 6
to enter those zones that require dial delay to be disabled;
these zones ignore the setting in entry 1)
UL: Dial delay plus entry delay must not exceed one minute; use zone
list 6 to disable dial delay from appropriate zones, if necessary.
∗
∗∗
∗53 SESCOA/Radionics Select [0]
0 = Radionics (0-9, B-F); enter “0” for all non-SESCOA formats
1 = SESCOA (0-9 only reporting)
∗
∗∗
∗54 Dynamic Signaling Delay [0]
Select delay from 0 to 225 secs, in 15-sec increments.
0 = no delay (both signals sent); 1 = 15 secs; 2 = 30 secs, etc.
NOTE: If ∗55 is set to “0,” use min. 30 sec to avoid redundant IP
report.
However, this value may need to be adjusted (ex. 45 secs)
depending on the reporting environment.
For UL Burglar Alarm installations with Line Security, must be “0”
∗
∗∗
∗55 Dynamic Signaling Priority / [0]
AAV Enable
0 = Primary Dialer first/ using AAV via phone line
1 = IP/GSM module first / not using AAV
For UL Commercial Burglary installations that use a DACT and
IP/GSM, this field must be “0”.
∗
∗∗
∗56, ∗
∗∗
∗57, ∗
∗∗
∗58 Menu Modes
These are Menu Mode commands, not data fields, for Zone Programming,
Function Key Programming, and Expert Mode Zone Programming respectively.
See page 2 and respective sections later in this document.
TO PROGRAM SYSTEM STATUS, & RESTORE REPORT CODES (∗
∗∗
∗59 thru
∗
∗∗
∗68, *70 thru ∗
∗∗
∗76, and ∗
∗∗
∗89):
For 3+1 or 4+1 Standard Format: Enter a code in the
first
box: 1–9, #+10 for
0, #+11 for B, #+12 for C, #+13 for D, #+14 for E, #+15 for F.
A 0 (
not
#+10) in the
first
box will disable a report. A 0 (
not
#+10) in the
second
box will result in automatic advance to the next field.
For Expanded or 4+2 Format: Enter codes in
both
boxes (1st and 2nd digits)
for 1–9, 0, or B–F, as described above.
A 0 (
not
#+10) in the
second
box will eliminate the expanded message for
that report. A 0 (
not
#+10) in
both
boxes will disable the report.
For Ademco Contact ID® Reporting: Enter any digit (other than 0) in the
first
box, to enable zone to report (entries in the
second
boxes are ignored).
A 0 (
not
#+10) in the
first
box disables the report.
UL: see installation instructions for requirements
SYSTEM STATUS REPORT CODES (
✱
59–
✱
68)
∗
∗∗
∗59 Exit Error Alarm Report Code [0]
See above for entries. V21iPSIA: [1] Always enabled.
∗
∗∗
∗60 Trouble Report Code [10] |
∗
∗∗
∗61 Bypass Report Code [00] |
∗
∗∗
∗62 AC Loss Report Code [10] |
∗
∗∗
∗63 Low Bat Report Code [10] |
∗
∗∗
∗64 Test Report Code [00] |
Use Scheduling mode to set periodic test reports, or use the following
key commands:
installer code +[#] + [0] + 0 = test report sent every 24 hours
installer code +[#] + [0] + 1 = test report sent once per week
installer code +[#] + [0] + 2 = test report sent every 28 day
Each mode sets schedule 32 to the stated repeat option; first test report
sent 12 hours after command.
∗
∗∗
∗65 Open Report Code [0,0,0]
Part. 1 Part. 2 Common
∗
∗∗
∗66 Arm Away/Stay Rpt Code
[0,0,0,0,0,0]
Away Stay Away Stay Away Stay
Part. 1 Part. 2 Common
∗
∗∗
∗67 RF Trans. Low Bat Report Code [00] |
UL: must be enabled if wireless devices are used
∗
∗∗
∗68 Cancel Report Code [00] |
V21iPSIA: [10] Report enabled.
∗
∗∗
∗69 Recent Closing Report Code [11] |
V21iPSIA:Always enabled.
Field does not apply to other controls.
RESTORE REPORT CODES (
✱
70 –
✱
76)
∗
∗∗
∗70 Alarm Restore Rpt Code [0]
∗
∗∗
∗71 Trouble Restore Rpt Code [00] |
∗
∗∗
∗72 Bypass Restore Rpt Code [00] |
∗
∗∗
∗73 AC Restore Rpt Code [00] |
∗
∗∗
∗74 Low Bat Restore Rpt Code [00] |
∗
∗∗
∗75 RF Trans. Lo Bat Rst Rpt Code [00] |
UL: must be enabled if wireless devices are used
∗
∗∗
∗76 Test Restore Rpt Code [00] |
OUTPUT AND SYSTEM SETUP (
✱
77 –
✱
93)
∗
∗∗
∗77 Daylight Saving Time [3][11] |
Start/End Month
0 = Disabled
1-12 = January-September (1 = Jan, 2 = Feb, etc)
#+10 = October; #+11 = November; #+12 = December
∗
∗∗
∗78 Daylight Saving Time [2][1] |
Start/End Weekend
0 = disabled; 1 = first; 2 = second; 3 = third; 4 = fourth;
5 = last; 6 = next to last; 7 = third to last
∗
∗∗
∗79, *80, *81, *82 Menu Modes
These are Menu Mode commands, not data fields, for Output Device Mapping,
Output Programming, Zone List Programming, and Alpha Programming
respectively. See page 2 and their respective sections in the Installation and
Setup Guide for procedures.
∗
∗∗
∗84 Auto Stay Arm [3]
0 = no; 1 = partition 1 only; 2 = partition 2 only; 3 = both partitions
∗
∗∗
∗85 Cross Zone Timer [0]
This option not for use in UL installations.
(assign cross zones on zone list 4, using *81 Menu mode)
0 = 15 seconds 6 = 2-1/2 min #+12 = 8 min
1 = 30 seconds 7 = 3 min #+13 = 10 min
2 = 45 seconds 8 = 4 min #+14 = 12 min
3 = 60 seconds 9 = 5 min #+15 = 15 min
4 = 90 seconds #+10 = 6 min
5 = 2 minutes #+11 = 7 min
NOTE: Cross zoning takes effect only after Exit Delay expires.
∗
∗∗
∗86 Cancel Verify Keypad Display [1]
0 = no “alarm canceled” display
1 = display “Alarm Canceled” when system is disarmed after an alarm
has occurred. (To clear the “ALARM CANCELED” display, the
user must enter the security code + OFF again.)