ERV/HRVVentilationSystems69-2480EF—01 13
Ensurethatyouhaveallofthefollowinginstallationitems:
InstallationSteps
2
Installation Area
1
Installation Kit
TheERV/HRVunitshouldbeinstalledinamechanicalroomorasclosetoanoutsidewallaspossible.
TheERV/HRVunitmustalwaysbeinstalledinanareawheretheairisconditionedtoavoidfreezingthe
condensateline.
Thecontractorshouldinstalltheunitinanareathatallowsthehomeownereasyaccessformaintenance.
Itisveryimportanttoinstallanelectricreceptacle(120Vac)neartheunit,aseparatecircuitbreaker
isalsorecommended.ItisbesttohaveaccesstoacondensatedrainneartheERV/HRVunittoavoid
havingtouseacondensatepump.
NOTE: Installationisnotrecommendedinunconditionedareassuchasanatticorcrawlspacewhere
thetemperaturecanfallbelow32ºF(0ºC).
NOTE: Ductinginunconditionedareasmustbefullysealedandinsulated.
InstallationKit:
•2Flexible6in.VinylDucts
•1CondensationDrainLine(10in.)
•1DrainAdapterwithNut
•4TieWraps(30in.)
•16Hex-headscrews(1/4x5/8in.)
•4Hex-headscrews(1/4x1in.)
•4Washers
•1Draincap(VNT5250E100andVNT5200E1000only)
•1powercord,120Vac(notshown)
4DuctCollars