Do you have a question about the horiba F-74BW and is the answer not in the manual?
Temperature Resolution | 0.1 °C |
---|---|
Waterproof Rating | IP67 |
pH Measurement Range | 0.00 to 14.00 pH |
Calibration Points | Up to 5 points |
Display | LCD with backlight |
Power Supply | 4 x AA batteries or AC adapter |
Lists the measurable parameters of the F-74BW meter.
Details the contents included in the F-74BW package.
Identifies and explains the parts and controls of the instrument.
Visual guide to navigating measurement modes for CH1 and CH2.
Visual guide for configuring instrument settings for CH1 and CH2.
Visual guide for accessing and operating data functions.
Steps for setting up the instrument, connecting electrodes, and power.
Procedures for configuring various instrument settings like calibration, memory, etc.
Configure standard solutions for pH calibration (NIST, USA, CUST).
Set automatic (ATC) or manual (MTC) temperature compensation.
Configure automatic data saving at regular intervals.
Set reminders for pH calibration intervals.
Assign IDs to samples for easier data retrieval.
Select units for ion measurement (g/L or mol/L).
Set the valency for ion measurement.
Select units for conductivity measurement (S/cm, S/m, mS/cm).
Set the temperature coefficient for conductivity compensation.
Input the cell constant for conductivity measurements.
Select units for salinity measurement (PPT or %).
Enable/disable automatic printing for measurement and calibration events.
Verify the functionality of the instrument's LCD display.
Test the connection and operation of an attached printer.
Configure the automatic power-off function to save energy.
Set the instrument's internal date and time.
Irreversibly delete all stored measurement data.
Clear stored calibration data for pH, ION, conductivity, and salinity.
View the count of stored measurement data entries.
Calibrate the instrument's temperature sensor.
Reset all instrument settings to their default values.
Enable or disable password protection for instrument operations.
Detailed instructions for calibrating pH, ION, Conductivity, and Salinity.
Step-by-step guide for pH calibration using NIST or USA standards.
Guidance on calibrating ion electrodes for accurate concentration measurements.
Procedures for calibrating conductivity measurements to ensure accuracy.
Instructions for performing a single-point salinity calibration.
Explains measurement functions like value hold, item changing, auto memory.
Hold the stable measurement value automatically or manually.
Switch between different measurement parameters (pH, ORP, ION, etc.).
How to use the auto data memory function for regular interval recording.
Print current or held measurement values.
Covers data memory, display, printing, and history functions.
Store current measurement data into the instrument's memory.
View previously stored measurement data on the screen.
Print stored measurement data from the instrument's memory.
View past calibration records for pH and ION measurements.
Print the recorded calibration history.
Display the history of pH check operations.
Print the pH check history data.
Guidance on cleaning and storing pH and ORP electrodes.
Instructions for maintaining various ion electrodes, including storage and conditioning.
Procedures for maintaining conductivity electrodes, focusing on long-term storage.
Lists common error messages and their solutions, plus general troubleshooting tips.
Table listing error codes, their messages, and definitions.
Troubleshooting steps for memory read/write issues (ERROR No.0001).
Troubleshooting for unstable readings (ERROR No.0003).
Troubleshooting for zero calibration errors (ERROR No.0004).
Troubleshooting for span calibration errors (ERROR No.0005).
Troubleshooting for buffer identification issues (ERROR No.0007).
Troubleshooting for calibration interval expiry (ERROR No.0008).
Troubleshooting for printer communication problems (ERROR No.0009).
Troubleshooting for exceeding memory capacity (ERROR No.0010).
Troubleshooting for cell constant errors (ERROR No.0011).
Troubleshooting for invalid key operations (ERROR No.000E).
Troubleshooting for fluctuating measurement readings.
Troubleshooting steps for slow instrument response.
Troubleshooting for unresponsive displays or readings.
Troubleshooting for blinking measurement values outside the display range.
Troubleshooting for a fixed or blinking temperature display.
Troubleshooting for inconsistent measurement results.
Troubleshooting steps when printer output fails.
Technical specifications for measuring objects and functions.
Detailed specs for pH measurement: range, resolution, repeatability.
Detailed specs for temperature measurement: range, resolution, repeatability.
Detailed specs for mV measurement: range, resolution, repeatability.
Detailed specs for ION measurement: range, resolution, repeatability.
Detailed specs for Conductivity measurement: range, resolution, repeatability.
Detailed specs for Resistivity measurement: range, resolution, repeatability.
Detailed specs for Salinity measurement: range, resolution.
Detailed specs for TDS measurement: range, resolution.
Lists key functions like PC interface, memory capacity, calibration points.
Lists the instrument's default configuration settings.
Lists available spare and optional parts for the instrument.