Specification
Electrical
Purpose of Control Electronic Immersion Heater Control for E7
Tariffs
Contact Rating 13A Amp 230V AC
(Suitable for Emmersion Heaters up to 3kW)
Contact Type Micro-disconnection
Switch Type Rocker switch, double-pole micro-disconnection
Supply 230V AC 50Hz only
Protection Class I
Control Action Type 1B,R
Operating Time Limitation Intermittent
Software Class Class A
Battery Type Lithium
Battery Life 2 Years
Display Custom LCD, Backlit
Clock 12 hour AM/PM
Display Time Adjustment 1 Minute Intervals
Switch Time Adjustment 1 Minute Steps
Programme Selection Off-Peak, 3 periods per day.
Programmable Boost & 1 Hour Manual Boost
Mechanical
Dimensions 170mm x 115mm x 60mm
Case Material Thermoplastic, flame retardant
o
Ball Pressure Test Temperature 75 C
Mounting Custom surface mounted back
box,.Independantly mounted
Environmental
Impulse Voltage Rating Cat III 4000V
Enclosure Protection Ip30
Pollution Degree Degree 2
o o
Operating Temperature Range 0 C to +35 C
Compliance
Design Standard EN 60730-2-7 RoHS
BEAB Approved
7