6
Motor
Manual
Outdoor storage
If the motor must be stored outdoors, never leave the motor
as is in the standard transport packaging. Instead the motor
must be:
Taken out of its plastic wrap.
Covered to completely prevent rain from entering the
motor. The cover should allow ventilation of the motor.
Placed on at least 100 mm (4”) high rigid supports, to
ensure that no moisture can enter the motor from be-
low.
Protected against harmful insects and vermin.
Packed in special outdoor packaging.
Drain plugs
The motor is equipped with drain plugs to let condensa-
tion water drain out. The drain plugs should be open when
stored.
Horizontal mounting: For horizontally mounted motors,
drain plugs are fitted at each end of the motor.
Vertical mounting: For vertically mounted motors, a mini-
mum of two drain plugs are fitted on the lower end shield.