EasyManua.ls Logo

HP 12C - Part II Programming

HP 12C
165 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
102
1. Key in the program and press CLEAR .
2. For each input pair of values, key in the y-value and press , key
in the corresponding x-value and press .
3. After all data pairs are input, press 06 to obtain the
correlation coefficient (between ln y and x).
4. Press to obtain A.
5. Press to obtain B.
6. Press to obtain the effective growth rate as a decimal.
7. To make a y-estimate, key in the x-value and press . For subsequent
estimates, key in the x-value and press 25 .
8. For a different set of data, press CLEAR and go to step 2.
REGISTERS
n: Unused i: Unused
PV: Unused PMT: Unused
FV: Unused
R
0
: Unused
R
1
: n R
2
: Σx
R
3
: Σx
2
R
4
: Σy
R
5
: Σy
2
R
6
: Σxy
R
7
-R
.6
: Unused
Keystrokes Display
CLEAR
45 1
1.00 First data pair input.
51.5 2
2.00 Second data pair input.
53.75 3
3.00 Third data pair input.
80 4
4.00 Fourth data pair input.
122.5 5
5.00 Fifth data pair input.
210 6
6.00 Sixth data pair input.
06
0.95
Correlation coefficient (between ln
y and x).

Table of Contents

Other manuals for HP 12C

Related product manuals