Model
1740A
General
Information
SECTION
|
GENERAL
INFORMATION
1-1.
INTRODUCTION.
1-2.
The
Hewlett-Packard
Model
1740A
is
a
dual-
channel,
100-MHz,
delayed
sweep
oscilloscope
de-
signed
for
general-purpose
bench
or
field
use.
The
dual-channel
vertical
deflection
system
has
12
cali-
brated
deflection
factors
from
5
mV/div
to
20
V/div.
Input
impedance
is
selectable
(50
ohms
or
1
megohm)
to
meet
various
measurement
requirements.
The
horizontal
deflection
system
has
calibrated
sweep
rates
from
2
s/div
to
0.05
us/div
and
delayed
sweep
rates
from
20
ms/div
to
0.05
us/div.
A
10X
magnifier
expands
all
sweeps
by
a
factor
of
10
and
extends
the
fastest
sweep
to
5
ns/div.
In
alternate
or
chop
modes,
the
trigger-view
control
feature
will
display
three
signals:
channel
A,
channel
B,
and
trigger
signal.
This
allows
correlation
of
the
time
between
the
trigger
signal
and
the
channel
A
and
channel
B
signals.
With
the
A
VS
B
control,
an
X-Y
mode
of
operation
is
possible.
The
channel
A
input
(Y-axis)
is
plotted
versus
the
channel
B
input
(X-axis).
1-3.
This
manual
contains
installation
and
operating
instructions,
as
well
as
maintenance
information
for
the
Model
1740A.
Instrument
specifications
and
pro-
cedures
for
verifying
proper
operation
are
included.
Procedures
are
also
included
for
adjusting
the
instru-
ment
to
its
performance
specifications.
Schematic
diagrams,
the
theory
of
operation,
and
troubleshooting
information
are
provided
for
use
in
maintaining
the
instrument.
1-4,
This
section
of
the
manual
contains
the
perform-
ance
specifications
for
the
Model
1740A,
and
a
list
of
the
options
available.
It
also
lists
the
accessories
sup-
plied
with
the
Model
1740A
and
other
accessories
that
are
available.
Instrument
and
manual
identification
in-
formation
are
also
included.
1-5.
SPECIFICATIONS.
1-6.
Table
1-1
is
a
complete
list
of
the
Model
1740A
critical
specifications
that
are
controlled
by
tolerances.
Table
1-2
contains
general
information
that
describes
operating
characteristics
of
the
Model
1740A.
1-7.
Any
change
in
the
specifications
due
to
manufac-
turing,
design,
or
traceability
to
the
U.S.
National
Bureau
of
Standards
will
be
listed
on
a
manual
change
sheet
included
with
this
manual.
The
manual
and
manual
change
sheet
supersede
all
previous
infor-
mation
concerning
specifications
of
the
1740A.
1-8.
ACCESSORIES
SUPPLIED.
1-9.
The
following
accessories
are
supplied
with
the
1740A:
One
Blue
Light
Filter,
HP
Part
No.
01740-02701
One
Front-panel
Cover,
HP
Part
No.
5040-0516
One
Accessory
Storage
Pouch,
HP
Part
No.
1540-
0292
Two
10:1
Divider
Probes,
HP
Model
No.
10006D
1-10.
ACCESSORIES
AVAILABLE.
1-11.
The
following
accessories
are
available
for
the
1740A:
Model
10002A
50:1
Divider
Probe
Model
10004D
10:1
Divider
Probe
Model
10007B
1:1
Divider
Probe
Model
10020A
Resistive
Divider
Prove
Kit
(Divi-
sion
ratios
of
1:1,
5:1,
10:1,
20:1, 50:1,
and
100:1)
Model
10173A:
RFI
Metal
Mesh
Contrast
Screen
Model
10140A:
Collapsible
Viewing
Hood
Model
197A:
Oscilloscope
Camera
(Requires
a
Model
10376A
Adapter
for
mounting
on
1740A)
Models
1001A, 1002A,
and
1114A:
Testmobiles
(All
accept
the
Model
1740A
and
provide
mobile
stands
for
the
oscilloscope)
1-12.
OPTIONS.
1-13.
The
options
listed
below
extend
the
usefulness
of
the
Model
1740A.
OPTION
001.
Option
001
replaces
the
standard
de-
tachable
power
cord
with
a
captive
power
cord.
There
are
two
standard
options
available
that
install
a
special
CRT
in
the
standard
instrument.
The
only
difference
between
the
optional
CRT
and
the
standard
CRT
is
the
phosphor
used
in
the
CRT.
Option
007
uses
P7
phos-
phor
and
Option
011
uses
P11
phosphor.
OPTION
090.
This
option
omits
the
two
Model
10006D
divider
probes
normally
supplied
as
accessories.
Other
probes
listed
under
Accessories
Available,
which
are
more
suitable,
may
be
specified.
OPTION
101.
Option
101
is
designed
for
optimum
per-
formance
with
the
HP
Model
1607A
Logic
State
An-
alyzer
to
provide
both
digital
logical
state
and
analog
electrical
analysis.
(Refer
to
Section
IV
for
circuit
de-
tails
and
Section
VI
for
a
list
of
replaceable
parts
in
Option
101.)
1-1