EasyManua.ls Logo

HP 2610 - Known Issues; Release R.11.12 Known Issues; Release R.11.22 Known Issues

HP 2610
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
Known Issues
Release R.11.12
Known Issues
Release R.11.12
The following problems are known issues in release R.11.12.
SSH (PR_0000003592) — Repeatedly performing crypto key generation tasks, and then connecting
to the switch via SSH and executing a show ip ssh command may trigger a switch crash with a message
similar to the following.
TLB Miss: Virtual Addr=0x10385720 IP=0x10385720 Task='mSnmpCtrl'
Task ID=0x85cc0150 fp:0x85b93e60 sp:0x85cbff80 ra:0x10385720
sr:0x1000fc01
SSH (PR_0000004562) If an SSH client disconnects and reconnects SSH sessions in rapid
succession, this may trigger a switch crash that produces a message like the following.
TLB Miss: Virtual Addr=0x10385720 IP=0x10385720 Task='mSnmpCtrl'
Task ID=0x85cc0150 fp:0x85b93e60 sp:0x85cbff80 ra:0x10385720 sr:0x1000fc01
Workaround: Increase to at least a five-second interval between connections.
Release R.11.22
The following problem is a known issues in release R.11.21. (Never released.)
Crash (PR_0000003648) — When either source-port filtering or source-port named-
filtering is configured on a trunk port, and that trunk port becomes established within the
trunk, the switch crashes with a message similar to the following.
SubSystem 0 went down: 01/01/90 09:04:37 Software exception at
bcmHwFilters.c:403 -- in 'mAdMgrCtrl', task ID = 0x85e26c0

Table of Contents