EasyManua.ls Logo

HP 3457A - 3-44. Scanning

HP 3457A
273 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
3457A
3-42.
Input
Selection.
When
using
the
General
Purpose
Multiplexer,
the
instrument
must
be
set
for
Rear
or
Scanner
inputs.
©
To
select
Rear
Inputs
-
Press
the
TERM
/
M
configuration
key.
Use
the
}/AUTO
or
}/HOLD
scroll
key
to
display
REAR
or
SCANNER
and
press
the
ENT
/
LAST
ENTRY
key.
3-43.
Channel
Selection.
Only
one
input
channel,
either
2-wire
or
4-wire,
plus
one
actuator
channel
can
be
selected
at
a
time.
When
an
input
channel
is
closed,
the
channel
previously
closed
is
opened.
The
same
ap-
plies
to
the
actuator
channels.
©
To
select
an
input
channel
-
Press
the
CHAN
/
N
configuration
key,
enter
the
number
of
the
channel
to
be
closed
and
press
the
ENT
/
LAST
ENTRY
key.
©
To
close
one
of
the
actuator
channels
-
Press
the
Blue
SHIFT
key
then
the
OFFSET
COMP
/
C
key,
Use
the
}/HOLD
scroll
key
to
display
CLOSE.
Enter
the
number
of
the
actuator
channel
to
be
closed
(8
or
9)
and
press
the
ENT
/
LAST
ENTRY
key.
©
To
open
all
channels
-
Press
the
Blue
SHIFT
key
then
the
OFFSET
COMP
/C
key.
Use
the
|
/HOLD
scroll
key
to
display
CRESET
and
press
the
ENT
/
LAST
ENTRY
key.
3-44,
Scanning.
The
instrument
can
be
set
to
automatically
take
a
number
of
readings
and
store
them
in
memory.
This
makes
it
possible
to
measure
some
or
all
of
the
input
channels
and
recall
the
measurements
taken.
The
following
is
a
simple
procedure
to
measure
inputs
connected
to
channels
0
through
7
of
the
HP
44491A
Multiplexer.
©
Determine
the
type
of
measurement
you
wish
to
make
(Voltage,
Resistance,
Current,
Frequency/Period)
and
set
the
instrument
for
that
measurement
as
described
in
the
previous
paragraphs.
©
Select
the
Rear/Scanner
input
-
Press
the
TERM
/
M
configuration
key.
Use
the
t/AUTO
or
|
/HOLD
scroll
key
to
display
REAR:2
or
SCANNER:2
and
press
the
ENT
/
LAST
ENTRY
key.
©
Set
the
Trigger
to
Hold
-
Press
the
Blue
SHIFT
key
then
the
STORE
/
T
configuration
key.
Use
the
)/HOLD
scroll
key
to
display
the
TRIG
command.
Press
the
>
display
key
once
to
hold
the
command.
Use
the
f/AUTO
or
|/HOLD
scroll
key
to
display
HOLD:4
and
press
the
ENT
/
LAST
ENTRY
key.
©
Set
the
number
of
readings
for
the
number
of
measurements
to
be
made
(in
this
case
8)
-
Press
the
NRDGS
/
L
configuration
key,
enter
the
number
8
and
press
the
ENT
/
LAST
ENTRY
key.
©
Set
the
Scan
Advance
to
Auto
-
Press
the
SCAN
ADV/O
configuration
key.
Use
the
[/AUTO
or
}/HOLD
scroll
key
to
display
AUTO:2
and
press
the
ENT
/
LAST
ENTRY
key.
©
Enable
the
Reading
Memory
-
Press
the
CONFIG
/
P
configuration
key
then
the
ENT
/
LAST
ENTRY
key.
©
Allocate
Reading
Memory
space
(each
reading
requires
4
bytes
of
memory)
-
Press
the
Blue
SHIFT
key
then
the
TERM
/
M
configuration
key.
Use
the
|/HOLD
scroll
key
to
display
MSIZE.
Enter
the
number
32
(8
readings
times
4
bytes)
and
press
the
ENT
/
LAST
ENTRY
key.
©
Select
the
channels
to
be
measured
-
Press
the
Blue
SHIFT
key
then
the
RECALL
/
S
configuration
key.
Use
the
{/HOLD
scroll
key
to
display
SLIST.
Enter
the
number
of
each
channel
you
wish
to
measure
fol-
lowed
by
a
comma
(,)
to
separate
them
(example:
0,1,2,3,4,5,6,7).
Press
the
ENT
/
LAST
ENTRY
key.
(4s
many
as
16
single
digit
channel
numbers
or
8
double
digit
channel
numbers
can
be
entered
at
one
time.
The
number
of
read-
ings
(NRDGS)
should
be
set
for
the
number
of
channels
entered
).
3-7