INTRODUCTION
AND
DESCRIPTION
1.
The
Model
532A/B
direct-reading
frequency
me
ters
offer
good
accuracy
over
an
entire
waveguide
band.
The
meter
consists
of
a
TE^j^i
mode
resonant
cavity
coupled
to
a
waveguide
section.
When
tuned
to
resonance,
a
fraction
of
the
power
is
absorbed,
and
consequently
there
is
a
dip
of
about
1
dB
in
the
transmitted
power.
The
frequency
at
which
this
dip
occurs
may
be
read
directly
from
the
scale.
2.
The
high-Q
resonant
cavity
is
tuned
by
a
choke
plunger.
Adjustment
of
the
plunger
is
by
means
of
a
precision
lead
screw
which
is
spring-loaded
to
pre
vent
backlash.
There
are
no
sliding
contacts.
The
base
of
the
532A/B
will
accommodate
the
shaft
insert
of
a
waveguide
stand
such
as
the
HP
Model
11540A.
INSTALLATION
3.
UNPACKING
AND
INSPECTION.
4.
The
frequency
meter
was
carefully
inspected,
mechanically
and
electrically,
prior
to
shipment.
In
spect
it
for
mechanical
damage
incurred
i
n
transit,
check
for
supplied
accessories,
and
test
electrical
performance.
If
there
is
damage
or
deficiency,
notify
the
carrier
and
the
nearest
Hewlett-
Packard
office
(HP
offices
are
listed
at
the
rear
of
this
manual).
In
the
event
of
mechanical
damage,
the
packing
materials
and
carton
should
be
held
for
carrier's
inspection.
5.
REPACKAGING
FOR
SHIPMENT.
6.
USING
ORIGINAL
PACKAGING.
The
same
con
tainers
and
materials
used
in
factory
packaging
can
be
obtained
through
the
Hewlett-Packard
sales
and
service
offices
listed
at
the
rear
of
this
manual.
7.
If
the
Model
532A/B
is
being
returned
to
Hewlett-
Packard
for
servicing,
attach
a
tag
indicating
the
type
of
service
required,
return
address,
model
number
and
full
serial
number.
Also,
mark
the
container
FRAGILE
to
assure
careful
handling.
In
any
correspon
dence
refer
to
the
instrument
by
model
number
and
full
serial
number.
8.
USING
OTHER
PACKAGING.
The
following
general
instructions
should
be
used
for
repackaging
with
com
mercially-available
materials:
a.
Wrap
the
instrument
in
heavy
paper
or
plastic.
(If
shipping
to
a
Hewlett-Packard
service
office
or
center,
attach
a
tag
indicating
the
type
of
service
re
quired,
return
address,
model
number,
and
full
serial
number.)
b.
Use
a
strong
shipping
container.
A
double-wall
carton
made
of
350
pound
test
material
is
adequate.
c.
Use
enough
shock-absorbing
material
(3-
to
4-inch
layer)
around
all
sides
of
the
instrument
to
provide
firm
cushion
and
prevent
movement
inside
the
con
tainer.
Protect
the
dial
windows
with
cardboard.
d.
Seal
the
shipping
container
securely.
e.
Mark
the
shipping
container
FRAGILE
to
assure
careful
handling.
00245-5
Prtnt»d
in
U.S.A.
00532-90010
I
1501
Page
Mill
Road,
Palo
Alto,
California,
U.S.A.,
Cable:
"HEWPACK"
Tel:
(415)
326-7000
Europe:
54
Route
Des
Acacias,
Geneva,
Switzerland,
Cable:
"HEWPA
CKSA
"
Tel.
(022)
42.81.50
Question and Answer IconNeed help?

Do you have a question about the HP 532A and is the answer not in the manual?

HP 532A Specifications

General IconGeneral
BrandHP
Model532A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals