EasyManuals Logo

HP 5385A User Manual

HP 5385A
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #55 background imageLoading...
Page #55 background image
•
•
•
HP 5384A
and
HP 5385A
Performance
Tests
Table 4-1.
Performance
Test
(Continued)
HP 8656A
SIGNAL GENERATOR
TIME
BASE
OUT
EXT
10
MHz HP 5384AIHP 5385A
REF FREQUENCY
COUNTER
RF
OUTPUT
BNC CABLE
HP
10100C
500
FEEDTHROUGH
Figure
4-2.
Channel
A Frequency Response
and
Sensitivity
Test
Setup
for
HP
5384A/HP
5385A
2.
Set
the
HP
8656A
to
output
a
20
MHz
sinewaveat
15
mV
rms.lncrease
the
frequency
of
the
HP
8656A
and
verify
the
counter
displays
the
proper
frequency
from
20
MHzto
100 MHz.
Record
the
results
on
the
test
card
(Pass/Fail).
Ill. CHANNEL B FREQUENCY RESPONSE AND SENSITIVITY TEST FOR HP 5384A
Description:
A signal
generator
with a
calibrated
output
is
set
to
the
specified
HP 5384A
channel
B
minimum
signal
sensitivity
level. The
frequency
is
slowly
increased
from
50
MHz
up
to
225
MHz
at a
constant
level,
and
the
HP
5384A
reading
is
checked
for
the
proper
count.
Specifications:
50
MHz
to
225
MHz:
10
mV
rms,
sinewave,
50
MHz
to
200
MHz
15
mV
rms,
sinewave,
200
MHz
to
225
MHz
a.
50
MHz
to
200
MHz
1.
Connect
the
HP
8656A
signal
generator
to
the
HP
5384A
B
channel
input
as shown
in
Figure 4-3.
HP 8656A
SIGNAL GENERATOR
TIME
BASE
OUT
EXT
10
MHz HP 5384A
REF
FREQUENCY COUNTER
1
/lf'ifj;i;:;::e:;z;:;::
r1.'i
z11
I
INPUT B
RF
OUTPUT
BNC CABLE
Figue 4-3.
Channel
B
Frequency
Resonse
and
Sensitivity
Test
Setup
for
HP 5384A
4-3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?