See
Also
Horizontal
Time/Div
Softkey
Time/Div
Softkey
The
top
softkey
in
the
horizontal
menu
is
the
time
/div
softkey,
which
displays
the
horizontal
scaling
factor.
When
the
scope
is
running,
this
softkey
also
displays
the
current
sample
rate.
You
can
use
the
horizontal
knob
to
change
the
time
base
scaling
at
any
time,
even
if
you
are
in
a
different
menu
or
when
the
time/div
softkey
is
not
the
active
function.
However,
when
the
time/div
softkey
is
the
active
function,
you
can
use
either
the
horizontal
knob,
keypad,
or
the
entry
knob
to
change
the
horizontal
scaling.
Horizontal
scaling
changes
in
a
1-2-5
sequence
from
500
ps/div
to
5
s/div.
When
the
HP
54540
is
samping
at
1
GSa/s
in
the
real-time
mode,
the
500
ps
setting
is
not
available.
When
the
HP
54540
and
HP
54520
are
sampling
at
500
MSa/s
in
the
real-time
mode,
the
500
ps
and
1
ns
setting
are
not
available.
The
fine
key
does
not
affect
the
time
base
sequence
while
the
acquisition
is
running,
unless
the
auto
adjust
softkey
is
set
to
adjust.
The
horizontal
scale
setting
affects
the
sample
rate
at
which
the
oscilloscope
acquires
data,
except
when
the
sample
clock
softkey
is
set
to
adjust
in
the
real-time
mode.
When
the
scope
is
running,
the
current
sample
rate
is
displayed
below
the
time/div
setting
in
the
time
base
menu.
In
the
real-time
mode
and
with
the
acquisition
stopped,
the
time/div
knob
also
controls
the
zoom
feature.
By
observing
the
memory
bar,
you
can
tell
what
portion
of
the
memory
is
being
displayed.
An
acquisition
is
not
displayed
on
the
screen
until
all
data
is
available.
The
data
is
available
when
the
waveform
record
is
full.
The
advisory
"running"
is
displayed
after
the
scope
triggers.
When
the
sample
clock
and
record
length
are
set
such
that
it
takes
two
seconds
or
longer
to
collect
the
data,
the
advisory
"”
sec
(prestore)"
is
displayed
while
pretrigger
data
is
collected,
and
"x
sec
(poststore)"
is
displayed
while
posttrigger
data
is
collected.
These
messages
indicate
the
time
needed
to
complete
an
acquisition,
where
7
is
the
remaining
time
in
seconds,
and
continues
to
count
down
until
the
time
has
elapsed.
The
total
time
acquired
and
the
sample
rate
are
dependent
on
the
sample
clock
setting
and
the
selected
record
length
of
the
acquisition
(as
per
table
4-1).
"Repetitive/Real-Time
Softkey"
in
this
chapter
for
information
on
sampling
modes.
4-4