Option 005 Trigger System
(HP 54602B only)
Internal trigger Sensitivity
Performance remains unchanged
Coupling
Performance remains unchanged
Modes
Performance remains unchanged
Holdoff
Performance remains unchanged
TV triggering
Available on channels 1 and 2 only
TV line and field
0.5 division of composite sync for stable display
External trigger
Performance remains unchanged
Vertical output Connector
Rear panel BNC (f)
Source Impedance
50
Ω
(nominal)
Signal source
selected by internal trigger source
Amplitude
approximately 90mVp-p into 50
Ω
for a full scale display at full
bandwidth of the oscilloscope
TV Trigger output Connector
Rear panel BNC (f)
Amplitude
TTL
Pulse width
a function of TV trigger mode, Minimum approximately 5us in
line modes to the width of a field in field modes
Delay from Vertical Output
approximately 400ns.
Performance Characteristics
Option 005 Trigger System
(HP 54602B only)
5–14