EasyManuals Logo

HP 9800 SERIES User Manual

HP 9800 SERIES
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #119 background imageLoading...
Page #119 background image
78-78
80
81
82
83
8a
85
86
87
88
88
80
81
-
88
100
101
102
103
loa
9845B/C
Mainframe
References 10-5
Reserved for future use.
Cartridge
out
or
door
open. Also check to
see
if
interface
is
connected
proper-
ly.
Mass storage device failure. Possible power failure.
Mass storage device not present.
Check
mass storage unit specifier.
Write protected. Check the write-protection device
on
the
medium
or
drive.
Record
not
found. There
is
a
bad
spot
on
the medium.
Mass storage medium
is
not initialized.
Not a compatible
tape
cartridge.
Record
address
error; information
can't
be
read. Hardware failure.
Check
for a
dirty
read
head.
Read
data
error. Hardware failure. Check for a dirty
read
head.
Check read error.
Mass storage system error.
Reserved for future use.
Item
in
print using list
is
string
but
image specifier
is
numeric.
Item in print using list
is
numeric
but
image specifier
is
string.
Numeric field specifier wider
than
printer width.
Item
in
print using list has no corresponding image specifier.
ON
KBD
or
TOPEN not allowed
in
subprogram.
105
-
108
Reserved for future use.
1 1
0 Plotter type specification not recognized. Check spelling of
"GRAPHICS",
"9872A"
or "INCREMENTAL".
1 1 1 Plotter has not
been
specified. Check select codes.
1 1 2 No graphics hardware installed in the System 45B.
1 1
3 LIMIT specifications
out
of range.
1 1 a
98036
card improperly configured.
1 1 5 TDISP
not
allowed unless peripheral keyboard active.
1
16
TOPEN
is
active
on
another
select code.
117-
1
a8
Reserved for future use.
1
50
Improper select code.
1 5 1 A negative select
code
was specified that
does
not match
present
bus
address-
ing.
152
153
15a
155
156
Parity error.
Either insufficient input
data
to satisfy
enter
list,
attempt
to ENTER from
source
into source
or
enter
count
exhausted
without linefeed.
Integer overflow, or ENTER
count
greater than
32
767
bytes
or
16383
words.
Invalid interface register number. (Can only specify 4-7.)
Improper expression type
in
READIO, WRITEIO,
or
STATUS list.
157
No linefeed was found to satify I ENTER image specifier, or
no
linefeed
record
delimiter was found
in
512
characters of input.
I

Table of Contents

Other manuals for HP 9800 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 9800 SERIES and is the answer not in the manual?