Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Disable the switch and then attempt
configdownload.
Sometimes config file downloaded may cause the configdownload
command to crash.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Do not disable a switch immediately
after enabling if it's coming up with
a new FID for the first time. Wait for
at least 10 seconds before issuing
switchdisable.
After changing FID on HP StorageWorks 8/40 SAN Switch and then
performing switchenable, switchdisable, observed ASSERT.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Reboot the Encryption SAN Switch.
HA cluster member node, HP StorageWorks Encryption SAN Switch
faults as a result of slot power cycling its HA cluster peer (HP Storage-
Works DC Encryption FC Blade).
Fixed in Fabric OS 6.3.0
IPL file is not getting updated, when a PDCM matrix is activated using
WebTools with Active=Save Mode checked.
Fixed in Fabric OS 6.3.0
Fabric Watch failed to initialize on fully populated HP StorageWorks
DC SAN Backbone Director.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Avoid querying FcFeModuleName
or (connUnitPortFCId in AG
mode) MIB to avoid memory leak.
Memory leak when querying connUnitPortFCId in Access Gateway
(AG) mode and also when querying FcFeModuleName.
Fixed in Fabric OS 6.3.0
Occasionally during the firmware upgrade process, the 1250 processor
is still rebooting when the FCR routes are being processed, resulting
in missing FCR routes and an inability to route traffic across VEX ports.
Fixed in Fabric OS 6.3.0
CUP Port present CU-Busy on one path and never sending CU-End to
clear busy.
Fixed in Fabric OS 6.3.0
In B2E routed environment, when user executes pathinfo command
in BB querying for xlate domain, the switch may panic.
Fixed in Fabric OS 6.3.0
Observed kernel panic on a DC SAN Backbone Director in RTE module.
Fixed in Fabric OS 6.3.0
Switches leaking memory slowly over extended period while being
managed by DCFM.
Fixed in Fabric OS 6.3.0
Switchdisabling all switches in the fabric causing all HP Storage-
Works 4/256 SAN Director switches Out of Memory: Killed
process 2337 (iswitchd).
Fixed in Fabric OS 6.3.0
License problem observed after configdownload and QoS license
was checked for 4G platforms at CLI.
Fixed in Fabric OS 6.3.0
Unable to configure ports using configdownload.
Fixed in Fabric OS 6.3.0
Portcams and NS zonemembership data are missing for hard-zoned
ports.
Fixed in Fabric OS 6.3.0
Software was not enforcing a mandatory switch disable before config-
uring the backbone Fabric ID.