Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Do not use logical switches.
Failover when Logical Switch (LS) trans incomplete Observed and
Panic. Ficud terminated detected when FID is created
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Power off and then Poweri on the
Switch via OA.
ISMIC - When a reset of a HP-VC is done via the OA, the vcfcadm_
user password is NOT generated as seen from the console log, thereby
causing a NO COMM on the VCM.
Fixed in Fabric OS 6.3.0
Workarounds prior to code change:
1. Slotpoweroff and
slotpoweron always recovers the
blades. 2. DC04 SAN Director
reboots also recover the blades.
Swapping HP StorageWorks 32 port 8Gb FC blade with 48 port
blade in DC04 SAN Director initializes both to a Faulty-51 state.
Fixed in Fabric OS 6.3.0
Supportsave slot transfer failed for HP StorageWorks DC Switch
Encryption blade after FAULTY (79) code
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Instead of relying on auto-negotiation,
lock the switch port at 8 Gb.
8 Gb storage device failed to detect 8 Gb speed when port was locked
as a G_port.
Fixed in Fabric OS 6.3.0
Workaround prior to code change: 1.
Disable the target ports. 2. Remove
one initiator from the container. 3.
Start the rekey. 4. Add the initiator
back.
Pending Merge: While doing first time encryption to a LUN with more
than 1 initiator active at the same time, rekey operations slowed signi-
ficantly.
Fixed in Fabric OS 6.3.0
Fabric Change Event (161) is not delivered from Fabric OS to B-series
SMIA if proxy Switch is disabled.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Do not enable Top Talkers
concurrently with functionality that is
using frame redirection.
Data encryption backup jobs failing due to HP StorageWorks DC SAN
Director crash and reboot when Top Talkers are enabled with Frame
Redirection.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Add an ISL on the user port lower
than the lowest Fport on switch.
In FCR fabric, switch transmitting E_Port traffic to F_Port with EOFni
when there is no ISL placed lower than a F_Port
Fixed in Fabric OS 6.3.0
Multiple repetitions of port enable/disable might result in a lost route
in an HP StorageWorks 4/256 SAN Director configuration.
Fixed in Fabric OS 6.3.0
NO Comm observed when we removed HP VC switch from Bay 3 and
installed it in Bay 4.
Fixed in Fabric OS 6.3.0
Channel receiving RSCN with missing ports in payload after HPF key
on or off.
Fixed in Fabric OS 6.3.0
Software verify error occurred during supportsave on HP Storage-
Works DC SAN Backbone & DC04 SAN Directors.