Automatic document feeder (ADF)
NOTE: After removing the ADF assembly, place it on a clean, dry, and smooth surface.
You must calibrate the ADF and scanner after installing the ADF. See
Calibrate a replacement ADF
assembly on page 214.
1. Release two thumb screws, and then disconnect one connector.
Figure 6-46 Remove the ADF assembly (1 of 4)
2. Open the ADF.
Figure 6-47 Remove the ADF assembly (2 of 4)
212 Chapter 6 Removal and replacement ENWW