Event log message Description Comments
●
XX=02: Magenta density-
measurement abnormality
●
XX=03: Yellow density-
measurement abnormality
4. Touch Full Calibration.
5. Touch Calibrate.
54.0F.XX
●
XX=00: Black misregistration is out
of range.
●
XX=01: Cyan misregistration is out
of range.
●
XX=02: Magenta misregistration is
out of range.
●
XX=03: Yellow misregistration is out
of range.
1. Scroll to and touch Administration.
2. Scroll to and touch Print Quality.
3. Touch Calibration/Cleaning.
4. Touch Full Calibration.
5. Touch Calibrate.
54.14 CPR sensor abnormality 1. Scroll to and touch Administration.
2. Scroll to and touch Print Quality.
3. Touch Calibration/Cleaning.
4. Touch Full Calibration.
5. Touch Calibrate.
54.1E.XX Halftone calibration error. 1. Scroll to and touch Administration.
2. Scroll to and touch Print Quality.
3. Touch Calibration/Cleaning.
4. Touch Full Calibration.
5. Touch Calibrate.
55.06.01 The DC controller NVRM has an
abnormal read/write.
1. Turn the product off then on.
2. If the error persists, replace the DC
Controller. See
DC controller PCA
and tray on page 270.
55.06.02 The DC controller NVRM is not
accessible.
1. Turn the product off then on.
2. If the error persists, replace the DC
Controller. See
DC controller PCA
and tray on page 270.
55.901C DCC restored DCC NVRAM was restored from the
formatter.
61.00.01 Color table error This event occurs when the color table
cannot read a table from the disk and the
component reverts to the version in
RAM. The file could be corrupt, missing,
or the disk could have failed. No
messages display on the control panel.
67.XX.00 A system variable (XX) is out of range.
68 8X01 Permanent storage was reset to factory
default because the current value was not
valid.
470 Chapter 7 Solve problems ENWW