5. Remove four screws (callout 6).
NOTE: The screw at the lower back of the power supply is a ground screw. Make sure that this
screw is placed in the correct position when the power supply is reinstalled.
Figure 6-97 Remove the power supply (high-voltage; 4 of 7)
6
6. Release the FFC from the retainers (callout 7).
Figure 6-98 Remove the power supply (high-voltage; 5 of 7)
7