4. Type the PIN that was displayed in step 7 in Start the telnet server function at the product on page 117
at the prompt, and then press the Enter key.
IMPORTANT: Make sure to type the PIN correctly. After five incorrect PIN entries, the product
terminates the Remote Admin connection. The Remote Admin feature must be re-initiated at the
product. See
Start the telnet server function at the product on page 117.
Figure 2-13 Enter the PIN
5. The following screen displays when the correct PIN is entered and the Remote Admin connection is
successful. For information about the Pre-boot menu and options, see
Pre-boot menu options
on page 107.
NOTE: Because a Remote Admin connection is an unsecure telnet network protocol connection, the
following Pre-boot menu items are disabled for the remote telnet client computer.
●
The +3:Administrator menu 4:Change Password item.
●
The +3:Administrator menu 5:Clear Password item.
●
The +3:Administrator menu 6:Disk Manage item.
Figure 2-14 Remote Admin window
ENWW Pre-boot menu options 121