Environmental
Operational Environmental Extremes
Test Parameters/Conditions - Power applied, unit
operating on system ±5%
nominal supply voltage.
10°C 10% R.H. ? 24 hours
10°C 90% R.H. ? 24 hours
20°C 90% R.H. ? 24 hours
30°C 90% R.H. ? 24 hours
40°C 90% R.H. ? 24 hours
50°C 90% R.H. ? 24 hours
50°C 10% R.H. ? 24 hours
Storage Environmental Extremes
Test Parameters/Conditions
140°F (60°C) @ 80% R.H. for 96 hours
-22°F (-30°C) @ 20% R.H. for 48 hours
No power applied
Delta °C < 1.0°C/min
Delta % R.H. < 1.5% R.H./min
Approvals
USB-IF, WHQL, Compliant with USB Mass Storage Class Bulk only Transport Specification Rev. 1.0
Compliant Intel Front Panel I/O Connectivity Design Guide V. 1.3
FCC, CE, BSMI, C-Tick, VCCI, MIC, cUL, TUV-T