If the values are not within the range specified, an error will appear on the front panel. In this
case, try the following.
●
Repeat the calibration.
●
Replace the Line Sensor
See Line Sensor Assembly on page 298.
6. If you loaded the paper manually, you must now unload it and then reload it in the normal way,
before the calibration can continue. In this case, the following message is displayed.
When you have unloaded the paper, the front panel prompts you to load it in the normal way.
Load the paper, then press OK.
7. The printer starts to calibrate the Line Sensor position to the black printhead. It prints a line of
black dots and then scans them:
8. When the Line Sensor has been calibrated, the results are displayed on the front panel. Press OK
to finish the calibration or Cancel to exit.
9. The printer now aligns the printheads. When the following message appears, press OK to
continue or Cancel to exit.
ENWW
Entering the Service Calibrations menu
131